Biological evaluation planning skill implementing ISO 10993-1 for biocompatibility testing strategy
Scanned 9/2/2026
Install to Claude Code
npx -y skills add a5c-ai/babysitter --skill iso10993-evaluator --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of Iso10993 Evaluator?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/a5c-ai-iso10993-evaluator-babysitter)More formats (shields.io, HTML) on the badges page.
---
name: iso10993-evaluator
description: Biological evaluation planning skill implementing ISO 10993-1 for biocompatibility testing strategy
allowed-tools:
- Read
- Write
- Glob
- Grep
- Edit
- Bash
metadata:
specialization: biomedical-engineering
domain: science
category: Biocompatibility and Materials
skill-id: BME-SK-016
graph:
domains: [domain:biomedical-engineering]
skillAreas: [skill-area:statistical-analysis, skill-area:data-analysis, skill-area:compliance-automation]
workflows: [workflow:experiment-design, workflow:peer-review-cycle]
roles: [role:biomedical-engineer, role:lab-technician]
---
# ISO 10993 Evaluator Skill
## Purpose
The ISO 10993 Evaluator Skill supports biological evaluation planning per ISO 10993-1, determining biocompatibility testing requirements based on device categorization, contact type, and duration.
## Capabilities
- Device categorization (body contact, duration)
- Testing endpoint determination matrix
- Existing data evaluation guidance
- Equivalence assessment templates
- Gap analysis for testing requirements
- Biological evaluation plan generation
- Report template generation
- Risk-based testing strategy
- Alternative testing approaches
- Literature review guidance
- Toxicological risk assessment support
## Usage Guidelines
### When to Use
- Planning biocompatibility testing programs
- Evaluating existing biocompatibility data
- Assessing material equivalence
- Preparing biological evaluation reports
### Prerequisites
- Device materials identified
- Contact type and duration defined
- Manufacturing process documented
- Existing data compiled
### Best Practices
- Apply risk-based approach per ISO 10993-1:2018
- Evaluate existing data before new testing
- Consider material equivalence carefully
- Document rationale for testing decisions
## Process Integration
This skill integrates with the following processes:
- Biological Evaluation Planning (ISO 10993)
- Extractables and Leachables Analysis
- Biomaterial Selection and Characterization
- 510(k) Premarket Submission Preparation
## Dependencies
- ISO 10993 series standards
- FDA G95-1 guidance
- Material databases
- Testing laboratory capabilities
- Toxicological databases
## Configuration
```yaml
iso10993-evaluator:
contact-categories:
- surface-device
- external-communicating
- implant
contact-types:
- skin
- mucosal-membrane
- breached-surface
- blood-path-indirect
- tissue-bone
- blood
duration-categories:
- limited
- prolonged
- permanent
```
## Output Artifacts
- Device categorization documents
- Testing requirement matrices
- Biological evaluation plans
- Gap analysis reports
- Equivalence assessments
- BER templates
- Literature review summaries
- Testing rationale documents
## Quality Criteria
- Categorization follows ISO 10993-1:2018
- Testing endpoints appropriate for device
- Existing data properly evaluated
- Equivalence arguments supported
- Gap analysis comprehensive
- Documentation supports regulatory review
Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.