Verify that an undervoltage protection opens both the main switch and the extra switch of a current limiter, each through a memory cell of its own, under clause 5.2.13.5.1 of ECSS-E-ST-20-20C. Use when one detection chain has to latch two series switches off and the two command paths share parts. Walk each path element by element, confirm every switch holds its open state in its own cell, name any memory or drive element the two paths hold in common, and run a single failure walk reporting wh...
Scanned 9/27/2026
Install to Claude Code
npx -y skills add ashfordeOU/aero-agent-skills --skill e2020-undervoltage-action-on-both-switches --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of E2020 Undervoltage Action On Both Switches?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/ashfordeou-e2020-undervoltage-action-on-both-switches)More formats (shields.io, HTML) on the badges page.
---
name: e2020-undervoltage-action-on-both-switches
description: "Verify that an undervoltage protection opens both the main switch and the extra switch of a current limiter, each through a memory cell of its own, under clause 5.2.13.5.1 of ECSS-E-ST-20-20C. Use when one detection chain has to latch two series switches off and the two command paths share parts. Walk each path element by element, confirm every switch holds its open state in its own cell, name any memory or drive element the two paths hold in common, and run a single failure walk reporting which switches stay closed. Trigger: ecss, e-st-20-20c, undervoltage-opens-both-switches, main-and-extra-switch-opening, independent-undervoltage-memory-cell, shared-undervoltage-memory-cell, undervoltage-off-command-path, limiter-extra-switch-latch."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
- id: ecss
reference-only: true
gated: false
domain: space-systems
pack: space-systems
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
domain: space-systems
subdomain: ecss
tags: [ecss, e-st-20-electrical-scope, e-st-20-20c, e2020-undervoltage-action-on-both-switches, undervoltage-opens-both-switches, main-and-extra-switch-opening, independent-undervoltage-memory-cell, shared-undervoltage-memory-cell, undervoltage-off-command-path, limiter-extra-switch-latch]
version: 0.1.0
author: Aero Agent Skills
---
# ECSS Power Supply — Undervoltage Action on Both Switches (space-systems/ecss/e2020-undervoltage-action-on-both-switches)
Use when the task is clause 5.2.13.5.1 of ECSS-E-ST-20-20C: the undervoltage
protection of a current limiter has to open the main switch and the extra
switch, and each open state has to be held by a memory cell of its own. This
leaf takes the two command paths and walks them element by element.
## Domain quick reference
- The clause names two switches because the limiter has two. The extra switch
exists so that the output can still be removed when the main switch has
failed; an undervoltage action that opens only the main switch leaves the
one device that was supposed to cover that failure closed.
- A command is not a state. The undervoltage detection raises an off command
for as long as the bus is low, and a bus that recovers — because the load
was just removed — drops it again. Only a memory cell keeps the switch off
afterwards, so a path with no cell in it gives an oscillation, not a trip.
- Each switch needs its own cell. Two switches latched by one cell open
together and, more to the point, stay closed together when that cell fails
or is reset, which is the arrangement the separate extra switch was meant
to avoid.
- The drive stage behind the cells counts. Two independent memory cells that
reach the switches through one driver put both switches behind one part
again, and the walk has to reach past the cells to see it.
- A shared detection element is normal and is graded elsewhere. One
undervoltage sensing function serving both paths is the expected design;
whether that function is itself single failure tolerant belongs to the
shared-protection clause, so this leaf reports it and does not double-count
it as a defect here.
- Conformance is per switch, not per unit. The report names the role whose
path is broken, because "the protection works" is true of a unit where only
the main switch ever opens.
## Workflow
1. Validate the architecture: a named unit, exactly one main and one extra
switch, a non-empty command path per switch, and elements that declare a
known kind consistently across both paths.
2. Confirm the action reaches both switches with nothing failed.
3. Check each path for a memory cell and check that every cell it holds is
declared to hold its state; a path with no cell, or with a cell that
releases, is a finding against that switch by name.
4. Collect the elements the two paths hold in common and split them by kind:
a shared memory or drive element is a finding, a shared detection element
is a note.
5. Walk each distinct element as a single failure and record which switch
roles stay closed; elements that block both roles are the common mode
list.
6. Return the verdict: conformant only when both switches are reached, both
hold their open state, and no memory or drive element is common.
## Pitfalls
- Reading "the protection opens the limiter" as one action. It is two, and a
design that latches only the main switch passes every functional test on a
healthy unit while failing the case the clause exists for.
- Accepting a combinational off path with no memory in it. It removes the
load, the bus recovers, the command drops and the switch closes back into
the same fault; the trip has to be held, not merely issued.
- Counting two cells as independent because they carry different part
numbers. Independence is about what they share downstream, and a common
driver, gate resistor or opto behind them makes the pair one item again.
- Treating the shared undervoltage detection as this clause's defect. It is a
single point of the detection function and it is real, but it is graded by
the shared-protection clause; report it and keep the memory finding clean.
- Letting a reset line leak between the cells. A cell that another path can
clear is not holding its own state, and it is reported through the same
holds-state check rather than assumed away.
- Averaging the walk into one pass or fail. The report names the element and
the roles it blocks, because a point that closes one switch and a point
that closes both are different findings.
## Behavior contract (gate 3)
The architecture validation, path and memory-cell lookup, open-state holding
check, command reachability, shared-element split by kind, single failure
walk, common-mode collection and verdict are exercised by the gate 3 contract
test: scripts/test_e2020_undervoltage_action_on_both_switches.py against
scripts/e2020_undervoltage_action_on_both_switches_logic.py (stdlib unittest,
offline). Run:
python3 scripts/test_e2020_undervoltage_action_on_both_switches.py
## Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.