Use when a cell capacitance figure is quoted without saying which equivalent network it belongs to. Derive the equivalent circuit elements of a solar cell from one measured impedance per ECSS-E-ST-20-08C clause 11.1.4.2.1: split magnitude and phase into the series resistance and reactance, form the series capacitance, the loss tangent and the quality factor, transform that pair into the parallel capacitance and loss resistance, report the spread between the two forms, remove the declared cont...
Scanned 9/27/2026
Install to Claude Code
npx -y skills add ashfordeOU/aero-agent-skills --skill e2008-equivalent-network-calculation --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of E2008 Equivalent Network Calculation?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/ashfordeou-e2008-equivalent-network-calculation)More formats (shields.io, HTML) on the badges page.
---
name: e2008-equivalent-network-calculation
description: "Use when a cell capacitance figure is quoted without saying which equivalent network it belongs to. Derive the equivalent circuit elements of a solar cell from one measured impedance per ECSS-E-ST-20-08C clause 11.1.4.2.1: split magnitude and phase into the series resistance and reactance, form the series capacitance, the loss tangent and the quality factor, transform that pair into the parallel capacitance and loss resistance, report the spread between the two forms, remove the declared contact and lead resistance, then close by rebuilding the measurement from the derived network. Trigger: ecss, e-st-20-08c-clause-11-1-4-2-1, solar-cell-equivalent-network, series-to-parallel-impedance-conversion, cell-loss-tangent, cell-quality-factor, contact-series-resistance-correction, impedance-closure-residual."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
- id: ecss
reference-only: true
gated: false
domain: space-systems
pack: space-systems
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
domain: space-systems
subdomain: ecss
tags: [ecss, e-st-20-08-photovoltaic-assembly-scope, e2008-equivalent-network-calculation, solar-cell-equivalent-network, series-to-parallel-impedance-conversion, cell-loss-tangent, cell-quality-factor, contact-series-resistance-correction, impedance-closure-residual]
version: 0.1.0
author: Aero Agent Skills
---
# ECSS Photovoltaic Assemblies -- Equivalent Network Calculation (space-systems/ecss/e2008-equivalent-network-calculation)
Use when the task is clause 11.1.4.2.1 of ECSS-E-ST-20-08C -- turning
the impedance a bridge or analyser measured on a solar cell into the
element values of an equivalent network. The measurement is two numbers
at one frequency, a magnitude and a phase. A solar cell is not a
capacitor, so those two numbers do not name a capacitance until a
network has been chosen to hold them.
## Domain quick reference
- Two equivalent networks fit the same measurement exactly: a
resistance in series with a capacitance, and a resistance across a
capacitance. Both reproduce the measured impedance at the measurement
frequency, and neither is more correct than the other.
- They are nevertheless different numbers. C_p = C_s / (1 + D squared),
so the gap between the two forms is D squared over one plus D
squared. On a low-loss article that is parts per thousand and nobody
notices; on a lossy cell it is per cent, and a capacitance quoted
without naming its form is ambiguous by that amount.
- The loss terms are what connect the forms. The dissipation factor is
the series resistance over the magnitude of the series reactance --
equivalently the tangent of the angle by which the measurement falls
short of a quarter turn -- and the quality factor is its reciprocal.
R_p = R_s (1 + Q squared) follows from the same pair.
- The measured phase has to lie strictly between a quarter turn of lag
and zero. Zero is a pure resistance, a quarter turn is a lossless
capacitance no real cell presents, and a positive phase is an
inductive fixture -- a lead loop or a resonance -- that the
resolution cannot represent and must refuse rather than fold into a
capacitance.
- Contact and lead resistance adds to the measured series resistance
and belongs to the harness, not the cell. It is subtracted before the
cell's own series resistance is reported, and a harness term that
reaches a large share of the measurement means the fixture is
dominating the element being derived.
- The derivation closes on itself. Rebuilding the impedance from the
derived parallel pair returns the magnitude and phase that went in,
so a residual above representation error indicates the resolution,
not the measurement.
- An instrument that also prints a parallel capacitance is a second
opinion, not a confirmation: a disagreement between its readout and
the derived value usually means the two are resolving different
networks or different frequencies.
## Workflow
1. Take the magnitude, the phase and the measurement frequency, and
refuse the derivation when any of them is absent.
2. Validate the phase as capacitive and strictly inside the quadrant;
refuse a resistive, lossless or inductive measurement instead of
clamping it into range.
3. Resolve the magnitude and phase into the series resistance and the
series reactance, and invert the reactance into the series
capacitance at the measurement frequency.
4. Form the dissipation factor from the series pair and the quality
factor from its reciprocal.
5. Transform to the parallel form: the loss resistance from the
quality factor, the capacitance from the dissipation factor.
6. Report the spread between the two capacitances and raise it as a
finding once the two forms can no longer be used interchangeably.
7. Subtract the declared contact and lead resistance to leave the
cell's own series resistance, and report the share the harness
carried.
8. Rebuild the impedance from the derived parallel pair, take the
closure residual against the measurement, and reconcile any
instrument readout that was supplied.
9. Report every element, both forms, the loss terms and a verdict that
stays open while any finding stands.
## Pitfalls
- Quoting a capacitance with no network named. The figure is only
unambiguous while the cell is nearly lossless, and the reader has no
way to tell which form it was.
- Comparing a series capacitance from one instrument with a parallel
capacitance from another and calling the difference a measurement
error. It is the transform, and it is predictable from the loss.
- Leaving the contact and lead resistance inside the derived series
resistance. It biases the loss terms in one direction, which then
biases the parallel form through both the quality factor and the
capacitance.
- Folding a positive phase into a capacitance. An inductive reading is
a fixture fault -- a lead loop or a resonance near the measurement
frequency -- and resolving it as a capacitance hides the fault in a
plausible number.
- Treating the closure rebuild as decoration. It is the only check that
the resolution was carried out correctly at all, and it costs one
evaluation of the derived network.
- Comparing a spread or a deviation against its limit by bare
arithmetic. Both are quotients of floats that can land a few units in
the last place either side of a round fraction, so the comparison
absorbs that error while the limit itself is never relaxed.
- Reading an instrument's own parallel readout as confirmation of the
derivation. Until the frequency and the network form behind the
readout are known, agreement is a coincidence and disagreement is
undiagnosed.
## Behavior contract (gate 3)
The capacitive phase validation, series resolution, series capacitance,
dissipation and quality factors, series-to-parallel transform, network
spread, contact resistance correction and share, impedance rebuild,
closure residual and instrument readout reconciliation are exercised by
the gate 3 contract test:
scripts/test_e2008_equivalent_network_calculation.py against
scripts/e2008_equivalent_network_calculation_logic.py (stdlib unittest,
offline). Run:
python3 scripts/test_e2008_equivalent_network_calculation.py
## Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.