Use when verify that a spacecraft electrical power chain survives any single fault without dropping below the power its minimum mission objectives need, under ECSS-E-ST-20C clause 5.7.2: categorize each unit failure mode and its redundancy scheme, sum the essential minimum-mission load demand, recompute the surviving bus capability with each branch failed in turn, report every non-redundant essential function, and check the stored energy carries the essential load across a cold-standby switch...
Scanned 9/27/2026
Install to Claude Code
npx -y skills add ashfordeOU/aero-agent-skills --skill e20-spacecraft-bus-single-failure-tolerance --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of E20 Spacecraft Bus Single Failure Tolerance?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/ashfordeou-e20-spacecraft-bus-single-failure-tolerance)More formats (shields.io, HTML) on the badges page.
---
name: e20-spacecraft-bus-single-failure-tolerance
description: "Use when verify that a spacecraft electrical power chain survives any single fault without dropping below the power its minimum mission objectives need, under ECSS-E-ST-20C clause 5.7.2: categorize each unit failure mode and its redundancy scheme, sum the essential minimum-mission load demand, recompute the surviving bus capability with each branch failed in turn, report every non-redundant essential function, and check the stored energy carries the essential load across a cold-standby switchover outage. Trigger: ecss, e-st-20-electrical-scope, single-failure-tolerance, single-point-failure, power-chain-redundancy, cold-standby-reconfiguration, minimum-mission-power-demand, surviving-bus-capability, cross-strapped-power-branch."
license: Apache-2.0
compliance: STANDARDS-REF
standards:
- id: ecss
reference-only: true
gated: false
domain: space-systems
pack: space-systems
compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"
metadata:
domain: space-systems
subdomain: ecss
tags: [ecss, e-st-20-electrical-scope, e20-spacecraft-bus-single-failure-tolerance, single-failure-tolerance, single-point-failure, power-chain-redundancy, cold-standby-reconfiguration, minimum-mission-power-demand, surviving-bus-capability]
version: 0.1.0
author: Aero Agent Skills
---
# ECSS Electrical Engineering -- Spacecraft Bus Single-Failure Tolerance (space-systems/ecss/e20-spacecraft-bus-single-failure-tolerance)
Use when the task is the clause 5.7.2 robustness demonstration of
ECSS-E-ST-20C -- showing that no single fault anywhere in the
spacecraft electrical power chain takes the bus below the power the
minimum mission objectives require, neither in the steady state that
follows the fault nor during the switchover that recovers from it.
## Domain quick reference
- The chain is treated as a set of parallel contributing branches --
solar array sections, regulator branches, battery branches,
distribution paths -- each carrying the power it delivers to the
bus. Chain capability is the sum over branches, and the single-fault
case is that sum recomputed with one branch faulted.
- Each branch failure mode is categorized once into its effect on the
chain: loss of output (short circuit, open circuit, a switch stuck
open), degraded output (the branch still delivers a reduced
fraction), or loss of the control path (a switch stuck closed, a
lost command route). An unrecognized mode is rejected before it
reaches the arithmetic rather than being silently treated as benign.
- Each branch redundancy scheme is categorized into how it recovers:
single string recovers not at all and the fault is permanent; cold
standby recovers fully but only after a switchover outage; hot
standby and cross strapping recover with no interruption because the
alternate element is already powered and carrying the function.
- Two capability figures follow from that. The steady-state figure --
what the chain delivers once any redundancy has taken over -- is the
one compared against the minimum-mission demand. The transient
figure, which excludes a cold-standby branch for the length of its
outage, is what the battery has to make up while the spare is
switched in.
- Demand is the summed power of the loads flagged essential for the
minimum mission objectives, not the full load list. A payload left
unflagged is outside the minimum objectives and is excluded by
design; the flag, not the power number, is what decides.
- A non-redundant branch whose function the chain cannot do without --
a single battery, a single main regulator -- is a finding on its own
terms whatever the power arithmetic says, because losing the
function loses the bus regardless of the margin that remains.
- Capability meets demand when it equals or exceeds it. Both sides are
sums of floating-point numbers, so an equal case can land a few
units in the last place short; the comparison absorbs that
representation error rather than widening the engineering limit.
## Workflow
1. Categorize every branch failure mode into its chain effect and
every redundancy scheme into its recovery category; reject an
unrecognized mode or scheme, a duplicated branch identifier and an
empty chain before any capability is computed.
2. Sum the power of the loads flagged essential for the minimum
mission objectives to get the demand the clause protects.
3. Fail each branch in turn and recompute the steady-state chain
capability: a single-string branch contributes only its degraded
residual, a standby or continuously redundant branch contributes
its full capability again.
4. Flag every single fault whose surviving capability falls below the
demand, recording the branch, the capability and the redundancy
category that produced it.
5. Report every branch that is both essential by function and carries
no redundancy, independently of step 4.
6. For each cold-standby branch with a non-zero switchover time,
recompute the capability available during the outage, take the
deficit against the demand, convert it to watt-hours over the
outage, and flag a deficit the usable battery energy cannot cover.
7. Aggregate the capability, single-point and reconfiguration
findings; the chain is single-fault tolerant only when all three
lists are empty.
## Pitfalls
- Checking only the steady state after the fault and declaring
tolerance -- a cold-standby branch is absent for its whole switchover
time, and an essential load that outlives the stored energy during
that window has already failed the clause.
- Summing the whole load list as the demand instead of the loads
flagged essential -- the clause protects the minimum mission
objectives, and a full-service demand turns every ordinary
degradation into a false finding.
- Reading a healthy margin as proof that there is no single point of
failure -- a single battery branch with generous margin still takes
the bus down when it fails, and that is a design finding the
arithmetic never surfaces.
- Treating a degraded-output fault as a total loss -- a branch still
delivering a known fraction is worst-cased away, which hides the
branches that genuinely go to zero behind a wall of false positives.
- Treating cold standby as equivalent to hot standby because both end
up restoring capability; the difference is the outage, and it is
precisely the part clause 5.7.2 makes you size the battery for.
- Comparing a summed capability against a summed demand with a bare
greater-or-equal test -- an exactly compliant case can report a
shortfall of a few units in the last place, so the comparison must
absorb representation error without loosening the limit itself.
## Behavior contract (gate 3)
The failure-mode and redundancy categorization, minimum-mission
demand, post-fault and transient capability, single-point-failure and
reconfiguration-energy logic is exercised by the gate 3 contract test:
scripts/test_e20_spacecraft_bus_single_failure_tolerance.py against
scripts/e20_spacecraft_bus_single_failure_tolerance_logic.py (stdlib
unittest, offline). Run:
python3 scripts/test_e20_spacecraft_bus_single_failure_tolerance.py
## Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.