Verify that the system is configured so that data or information collected by the [organization-defined] is only reported to authorized individuals or
Scanned 9/3/2026
Install to Claude Code
npx -y skills add CyberStrikeus/CyberStrike --skill sc-42-1-reporting-to-authorized --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of Sc 42 1 Reporting To Authorized?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/cyberstrikeus-sc-42-1-reporting-to-authorized)More formats (shields.io, HTML) on the badges page.
---
name: "SC-42(1)_reporting-to-authorized-individuals-or-roles"
description: "Verify that the system is configured so that data or information collected by the [organization-defined] is only reported to authorized individuals or"
category: "configuration"
version: "5.2.0"
author: "cyberstrike-official"
tags:
- nist
- sp800-53
- rev5
- sc-42-1
- sc
- enhancement
tech_stack:
- aws
- azure
- gcp
- linux
- windows
- network
cwe_ids:
- CWE-311
chains_with: []
prerequisites:
- SC-42
severity_boost: {}
---
# SC-42(1) Reporting to Authorized Individuals or Roles
> **Enhancement of:** SC-42
## High-Level Description
**Family:** System and Communications Protection (SC)
**Framework:** NIST SP 800-53 Rev 5
In situations where sensors are activated by authorized individuals, it is still possible that the data or information collected by the sensors will be sent to unauthorized entities.
## What to Check
- [ ] Verify SC-42(1) Reporting to Authorized Individuals or Roles is documented in SSP
- [ ] Confirm control is operating effectively
- [ ] Review evidence of continuous monitoring for SC-42(1)
- [ ] Verify enhancement builds upon base control SC-42
## How to Test
### Step 1: Review Documentation
Examine the System Security Plan (SSP) and related artifacts for SC-42(1) implementation details. Verify the organization has documented how this control is satisfied.
### Step 2: Validate Implementation
```
# For cloud environments, use cloud-audit-mcp tools
# For on-premises, review system configurations directly
# Example: Check if account management policies exist
grep -r "account.management\|access.control" /etc/security/ 2>/dev/null
```
### Step 3: Test Operating Effectiveness
Verify the control is actively functioning, not just documented. Check logs, configurations, and operational evidence.
## Tools
| Tool | Purpose | Usage |
| --------------- | ------------------------------------- | ------------------------------------ |
| cloud-audit-mcp | Check encryption and network controls | `cloud_audit_encryption` |
| nmap | Network scanning | `nmap -sV --script ssl-enum-ciphers` |
## Remediation Guide
### Control Statement
Verify that the system is configured so that data or information collected by the [organization-defined] is only reported to authorized individuals or roles.
### Implementation Guidance
In situations where sensors are activated by authorized individuals, it is still possible that the data or information collected by the sensors will be sent to unauthorized entities.
## Risk Assessment
| Finding | Severity | Impact |
| --------------------------------------------------------------------- | -------- | ----------------------------------------------- |
| SC-42(1) Reporting to Authorized Individuals or Roles not implemented | High | System and Communications Protection |
| SC-42(1) partially implemented | Medium | Incomplete System and Communications Protection |
## CWE Categories
| CWE ID | Title |
| ------- | ------------------------------------ |
| CWE-311 | Missing Encryption of Sensitive Data |
## References
- [NIST SP 800-53 Rev 5 - SC-42(1)](https://csrc.nist.gov/projects/cprt/catalog#/cprt/framework/version/SP_800_53_5_1_1/home?element=sc-42.1)
- [NIST SP 800-53A Rev 5 (Assessment Procedures)](https://csrc.nist.gov/pubs/sp/800/53/a/r5/final)
- [NIST SP 800-53 Rev 5 Full Catalog](https://csrc.nist.gov/pubs/sp/800/53/r5/upd1/final)
## Checklist
- [ ] Control documented in SSP
- [ ] Implementation evidence collected
- [ ] Operating effectiveness validated
- [ ] Continuous monitoring in place
- [ ] Related controls (none) reviewed
Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.
No comments yet. Be the first to comment!