Establish configuration requirements, connection requirements, and implementation guidance for organization-controlled mobile devices, to include w...
Scanned 9/3/2026
Install to Claude Code
npx -y skills add CyberStrikeus/CyberStrike --skill AC-19_access-control-for-mobile-devices --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of AC 19 Access Control For Mobile Devices?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/cyberstrikeus-ac-19-access-control-for-mobile-devices)More formats (shields.io, HTML) on the badges page.
---
name: "AC-19_access-control-for-mobile-devices"
description: "Establish configuration requirements, connection requirements, and implementation guidance for organization-controlled mobile devices, to include w..."
category: "authorization"
version: "5.2.0"
author: "cyberstrike-official"
tags:
- nist
- sp800-53
- rev5
- ac-19
- ac
tech_stack:
- aws
- azure
- gcp
- linux
- windows
cwe_ids:
- CWE-284
chains_with:
- AC-3
- AC-4
- AC-7
- AC-11
- AC-17
- AC-18
- AC-20
- CA-9
- CM-2
- CM-6
prerequisites: []
severity_boost:
AC-3: "Chain with AC-3 for comprehensive security coverage"
AC-4: "Chain with AC-4 for comprehensive security coverage"
AC-7: "Chain with AC-7 for comprehensive security coverage"
---
# AC-19 Access Control for Mobile Devices
## High-Level Description
**Family:** Access Control (AC)
**Framework:** NIST SP 800-53 Rev 5
A mobile device is a computing device that has a small form factor such that it can easily be carried by a single individual; is designed to operate without a physical connection; possesses local, non-removable or removable data storage; and includes a self-contained power source. Mobile device functionality may also include voice communication capabilities, on-board sensors that allow the device to capture information, and/or built-in features for synchronizing local data with remote locations. Examples include smart phones and tablets. Mobile devices are typically associated with a single individual. The processing, storage, and transmission capability of the mobile device may be comparable to or merely a subset of notebook/desktop systems, depending on the nature and intended purpose of the device. Protection and control of mobile devices is behavior or policy-based and requires users to take physical action to protect and control such devices when outside of controlled areas. Controlled areas are spaces for which organizations provide physical or procedural controls to meet the requirements established for protecting information and systems.
Due to the large variety of mobile devices with different characteristics and capabilities, organizational restrictions may vary for the different classes or types of such devices. Usage restrictions and specific implementation guidance for mobile devices include configuration management, device identification and authentication, implementation of mandatory protective software, scanning devices for malicious code, updating virus protection software, scanning for critical software updates and patches, conducting primary operating system (and possibly other resident software) integrity checks, and disabling unnecessary hardware.
Usage restrictions and authorization to connect may vary among organizational systems. For example, the organization may authorize the connection of mobile devices to its network and impose a set of usage restrictions, while a system owner may withhold authorization for mobile device connection to specific applications or impose additional usage restrictions before allowing mobile device connections to a system. Adequate security for mobile devices goes beyond the requirements specified in [AC-19](#ac-19) . Many safeguards for mobile devices are reflected in other controls. [AC-20](#ac-20) addresses mobile devices that are not organization-controlled.
## What to Check
- [ ] Verify AC-19 Access Control for Mobile Devices is documented in SSP
- [ ] Validate all 2 control requirements are implemented
- [ ] Confirm control is operating effectively
- [ ] Review evidence of continuous monitoring for AC-19
## How to Test
### Step 1: Review Documentation
Examine the System Security Plan (SSP) and related artifacts for AC-19 implementation details. Verify the organization has documented how this control is satisfied.
### Step 2: Validate Implementation
```
# For cloud environments, use cloud-audit-mcp tools
# For on-premises, review system configurations directly
# Example: Check if account management policies exist
grep -r "account.management\|access.control" /etc/security/ 2>/dev/null
```
### Step 3: Test Operating Effectiveness
Verify the control is actively functioning, not just documented. Check logs, configurations, and operational evidence.
## Tools
| Tool | Purpose | Usage |
| --------------- | -------------------------------------- | -------------------------- |
| cloud-audit-mcp | Check IAM policies and access controls | `cloud_audit_iam_policies` |
| hackbrowser | Test web application access controls | `hackbrowser` |
## Remediation Guide
### Control Statement
Establish configuration requirements, connection requirements, and implementation guidance for organization-controlled mobile devices, to include when such devices are outside of controlled areas; and
Authorize the connection of mobile devices to organizational systems.
### Implementation Guidance
A mobile device is a computing device that has a small form factor such that it can easily be carried by a single individual; is designed to operate without a physical connection; possesses local, non-removable or removable data storage; and includes a self-contained power source. Mobile device functionality may also include voice communication capabilities, on-board sensors that allow the device to capture information, and/or built-in features for synchronizing local data with remote locations. Examples include smart phones and tablets. Mobile devices are typically associated with a single individual. The processing, storage, and transmission capability of the mobile device may be comparable to or merely a subset of notebook/desktop systems, depending on the nature and intended purpose of the device. Protection and control of mobile devices is behavior or policy-based and requires users to take physical action to protect and control such devices when outside of controlled areas. Controlled areas are spaces for which organizations provide physical or procedural controls to meet the requirements established for protecting information and systems.
Due to the large variety of mobile devices with different characteristics and capabilities, organizational restrictions may vary for the different classes or types of such devices. Usage restrictions and specific implementation guidance for mobile devices include configuration management, device identification and authentication, implementation of mandatory protective software, scanning devices for malicious code, updating virus protection software, scanning for critical software updates and patches, conducting primary operating system (and possibly other resident software) integrity checks, and disabling unnecessary hardware.
Usage restrictions and authorization to connect may vary among organizational systems. For example, the organization may authorize the connection of mobile devices to its network and impose a set of usage restrictions, while a system owner may withhold authorization for mobile device connection to specific applications or impose additional usage restrictions before allowing mobile device connections to a system. Adequate security for mobile devices goes beyond the requirements specified in [AC-19](#ac-19) . Many safeguards for mobile devices are reflected in other controls. [AC-20](#ac-20) addresses mobile devices that are not organization-controlled.
## Risk Assessment
| Finding | Severity | Impact |
| ------------------------------------------------------- | -------- | ------------------------- |
| AC-19 Access Control for Mobile Devices not implemented | High | Access Control |
| AC-19 partially implemented | Medium | Incomplete Access Control |
## CWE Categories
| CWE ID | Title |
| ------- | ----------------------- |
| CWE-284 | Improper Access Control |
## References
- [NIST SP 800-53 Rev 5 - AC-19](https://csrc.nist.gov/projects/cprt/catalog#/cprt/framework/version/SP_800_53_5_1_1/home?element=ac-19)
- [NIST SP 800-53A Rev 5 (Assessment Procedures)](https://csrc.nist.gov/pubs/sp/800/53/a/r5/final)
- [NIST SP 800-53 Rev 5 Full Catalog](https://csrc.nist.gov/pubs/sp/800/53/r5/upd1/final)
## Checklist
- [ ] Control documented in SSP
- [ ] Implementation evidence collected
- [ ] Operating effectiveness validated
- [ ] Continuous monitoring in place
- [ ] Related controls (AC-3, AC-4, AC-7, AC-11, AC-17) reviewed