Use when after extracting raw MS/MS spectra from mzML files when you observe high fragment counts per spectrum (e.g., 98 fragments) and want to reduce noise from instrument measurement uncertainty.
Scanned 9/12/2026
Install to Claude Code
npx -y skills add HolobiomicsLab/asb-skill-collections --skill spectral-peak-grouping-mass-tolerance --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of Spectral Peak Grouping Mass Tolerance?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/holobiomicslab-spectral-peak-grouping-mass-tolerance-asb-skill-collections)More formats (shields.io, HTML) on the badges page.
---
name: spectral-peak-grouping-mass-tolerance
description: Use when after extracting raw MS/MS spectra from mzML files when you observe high fragment counts per spectrum (e.g., 98 fragments) and want to reduce noise from instrument measurement uncertainty.
license: CC-BY-4.0
metadata:
edam_operation: http://edamontology.org/operation_3634
edam_topics:
- http://edamontology.org/topic_0121
- http://edamontology.org/topic_3370
tools:
- dures
- dplyr
- Spectra
- data.table
techniques:
- LC-MS
derived_from:
- doi: 10.1021/acs.analchem.5c01726
title: DuReS
evidence_spans:
- devtools::install_github("BiosystemEngineeringLab-IITB/dures", auth_token = NULL)
- invisible(lapply(c("dplyr", "readr", "data.table", "pbapply", "magrittr", "utils", "stats", "rPref", "ggplot2", "DEoptim", "patchwork", "S4Vectors", "Spectra"
- invisible(lapply(c("dplyr", "readr", "data.table", "pbapply", "magrittr", "utils", "stats", "rPref", "ggplot2", "DEoptim", "patchwork", "S4Vectors", "Spectra", "BiocManager", "knitr", "markdown"),
claims: []
provenance:
collection: https://w3id.org/holobiomicslab/asb-skill/collection/metabolomics/v2
assembled_by: scripts/collect_metabolomics_collection.py
sources:
- build: coll_dures_cq
doi: 10.1021/acs.analchem.5c01726
title: DuReS
dedup_kept_from: coll_dures_cq
schema_version: 0.2.0
attribution:
generator: AgenticScienceBuilder
original_doi: 10.1021/acs.analchem.5c01726
all_source_dois:
- 10.1021/acs.analchem.5c01726
zenodo_doi: 10.5281/zenodo.20794027
curators: []
promoter: Louis-Félix Nothias
sponsor: CNRS & Université Côte d'Azur
---
# spectral-peak-grouping-mass-tolerance
## Summary
Merge MS/MS spectral peaks (m/z and intensity) within a specified mass tolerance to reduce fragment redundancy and noise in tandem mass spectrometry data. This intra-spectrum grouping step consolidates nearby m/z values by averaging their positions and summing their intensities, typically reducing fragment counts by 10–20% before downstream denoising.
## When to use
Apply this skill after extracting raw MS/MS spectra from mzML files when you observe high fragment counts per spectrum (e.g., 98 fragments) and want to reduce noise from instrument measurement uncertainty. Use it as a preprocessing step before consensus spectrum generation or frequency-based denoising, especially when replicate spectra from the same feature show multiple near-duplicate peaks that differ only within your instrument's mass accuracy (typically 0.05 Da for orbitrap or 5 ppm for time-of-flight).
## When NOT to use
- Input spectra are already denoised or have been processed by another grouping algorithm; re-grouping may double-merge peaks.
- Your instrument mass accuracy is unknown or poorly characterized; choosing tolerance without validation can lose signal or retain noise.
- Inter-spectrum (cross-replicate) grouping is required instead; this skill only groups peaks within single spectra, not across replicates.
## Inputs
- mzML files (raw MS/MS spectra)
- preprocessed spectra object from preprocess()
- feature metadata (m/z, retention time, feature ID)
- mass tolerance parameter (Da or ppm)
## Outputs
- grouped spectra object with merged m/z and summed intensities
- fragment count per spectrum (post-grouping)
- peak data matrix (m/z × intensity) for grouped spectra
## How to apply
Load preprocessed MS/MS spectra using the preprocess() function with specified m/z and RT tolerances (e.g., 5 ppm m/z, 0.1 min RT). Apply extract_raw_spectra() with a mass tolerance parameter (default 0.05 Da) to group fragments within each individual spectrum by merging m/z values (arithmetic mean) and summing their intensities. Verify the grouping by extracting peak data using Spectra::peaksData() before and after grouping, comparing fragment counts to confirm reduction (e.g., 98 → 81 fragments). The tolerance should match your instrument's mass accuracy; tighter tolerances (0.05 Da) preserve more peaks, while looser tolerances (0.1+ Da) achieve greater consolidation at the risk of merging genuine distinct ions.
## Related tools
- **dures** (R package providing extract_raw_spectra() function to perform intra-spectrum fragment grouping within specified mass tolerance) — https://github.com/BiosystemEngineeringLab-IITB/dures
- **Spectra** (Bioconductor R package providing peaksData() to extract and inspect peak m/z and intensity matrices before and after grouping)
- **data.table** (R package for efficient manipulation of grouped peak data and fragment count aggregation)
- **dplyr** (R package for filtering and transforming spectral data before and after grouping)
## Examples
```
l2 = extract_raw_spectra(folder_path = folder_path, l1, 0.05, 0.8)
```
## Evaluation signals
- Fragment count reduction is monotonic and consistent with mass tolerance choice (e.g., tighter tolerance → smaller reduction; looser tolerance → larger reduction).
- Sum of pre-grouping and post-grouping intensities are equal or nearly equal for each spectrum (intensity is conserved during merging).
- Mean m/z of grouped peaks falls within the specified mass tolerance of the original constituent peaks (validate averaging arithmetic).
- Reported fragment counts match independently verified counts from external spectral files (e.g., MS2_scans_before_denoising .txt files) or manual spot-checks.
- No peaks disappear; final fragment count is strictly less than or equal to the input count (monotonic decrease or identity).
## Limitations
- Mass tolerance is global and uniform; instrument calibration drift or m/z-dependent accuracy variations are not modeled per-spectrum.
- Merging by arithmetic mean of m/z assumes equal reliability of all constituent peaks; weighted averaging by intensity may be more appropriate.
- Intra-spectrum grouping does not address cross-replicate redundancy; use inter-spectrum grouping or consensus spectrum generation for that.
- Very tight tolerances (e.g., 0.01 Da) may fail to merge true duplicates if instrumental noise exceeds the tolerance; very loose tolerances (e.g., 0.5 Da) risk merging distinct ions.
- No automatic validation that chosen tolerance matches instrument specs; user must supply or calibrate independently.
## Evidence
- [methods] After grouping, the number of fragments reduced to `81`: "After grouping, the number of fragments reduced to `81`"
- [methods] Apply extract_raw_spectra() with mass tolerance to group fragments by merging m/z values (mean) and summing intensities: "Apply extract_raw_spectra() with mass tolerance 0.05 Da to group fragments within each spectrum by merging m/z values (mean) and summing intensities."
- [methods] Fragments within default tolerance of 0.05 Da were merged: "fragments within a default tolerance of **0.05 Da** of one another were merged"
- [methods] Extract peak data using Spectra::peaksData() before intra-spectrum grouping for verification: "Extract peak data using Spectra::peaksData() before intra-spectrum grouping for features 1982 (spectrum scan_1587, expected 23 fragments)"
- [readme] DuReS extracts top x% TIC spectra and groups fragments within a specified mass tolerance: "Extract the top x% TIC spectra, and **Group fragments** within a specified **mass tolerance**"
- [methods] Fragment reduction from 98 to 81 fragments after intra-spectrum grouping: "Fragment reduction from 98 to 81 fragments after intra-spectrum grouping and labeling"