Use when processing raw LC/MS data (mzML or mzXML format) from multi-sample
Scanned 9/12/2026
Install to Claude Code
npx -y skills add HolobiomicsLab/asb-skill-collections --skill retention-time-mz-alignment --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of Retention Time Mz Alignment?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/holobiomicslab-retention-time-mz-alignment)More formats (shields.io, HTML) on the badges page.
---
name: retention-time-mz-alignment
description: Use when processing raw LC/MS data (mzML or mzXML format) from multi-sample
cohorts where retention time or intensity drift is suspected due to batch effects,
instrument calibration drift, or variable run order.
license: CC-BY-4.0
metadata:
edam_operation: http://edamontology.org/operation_3632
edam_topics:
- http://edamontology.org/topic_0625
- http://edamontology.org/topic_3172
tools:
- mzEmbed
- mzLearn
techniques:
- LC-MS
- ion-mobility-MS
license_tier: open
provenance_tier: literature
derived_from:
- doi: 10.1101/2025.01.26.634927v3
title: mzLearn
evidence_spans:
- mzEmbed, a framework for developing pre-trained generative models and fine-tuning
them for specific tasks for untargeted metabolomics datasets
claims: []
provenance:
collection: https://w3id.org/holobiomicslab/asb-skill/collection/metabolomics/v2
assembled_by: scripts/collect_metabolomics_collection.py
sources:
- build: coll_mzlearn_cq
doi: 10.1101/2025.01.26.634927v3
title: mzLearn
dedup_kept_from: coll_mzlearn_cq
schema_version: 0.2.0
attribution:
generator: AgenticScienceBuilder
original_doi: 10.1101/2025.01.26.634927v3
all_source_dois:
- 10.1101/2025.01.26.634927v3
zenodo_doi: 10.5281/zenodo.20794027
curators: []
promoter: Louis-Félix Nothias
sponsor: CNRS & Université Côte d'Azur
---
# retention-time-mz-alignment
## Summary
Autonomous correction of retention time (RT) and m/z drift across LC/MS samples caused by batch effects and run-order variation, enabling consistent feature detection and quantification without manual parameter tuning. This skill is essential for large-scale metabolomics cohorts where instrumental drift would otherwise compromise signal reproducibility.
## When to use
Apply this skill when processing raw LC/MS data (mzML or mzXML format) from multi-sample cohorts where retention time or intensity drift is suspected due to batch effects, instrument calibration drift, or variable run order. This is particularly critical when handling large-scale datasets (hundreds to thousands of files) where manual per-file parameter adjustment is infeasible, or when downstream pre-trained generative models require aligned, normalized feature matrices as input.
## When NOT to use
- Input is already a processed feature table (e.g., from xcms, MS-DIAL, or another peak picker) — skip directly to downstream annotation or modeling.
- Targeted LC/MS or SRM/MRM data where m/z and RT windows are pre-defined — mzLearn is designed for untargeted discovery.
- Very small cohorts (<5 files) where batch drift estimation is unreliable or where manual parameter tuning is more practical than automated learning.
## Inputs
- Raw LC/MS data files (mzML or mzXML format)
- Multi-sample cohort (no minimum size, but scalability tested to 2,075 files)
## Outputs
- Feature abundance table (CSV or mzTab format) with columns: median retention time, m/z value, normalized intensity per sample
- Detected metabolite signals defined by m/z and RT coordinates
## How to apply
Load raw LC/MS data files in mzML format into mzLearn, which autonomously learns signal characteristics across the cohort through iterative refinement. The algorithm corrects for retention time drift by identifying consistent m/z and RT landmarks across samples and realigning features to median RT and m/z values within each feature group. Intensity normalization is performed across samples to correct for run-order and batch-dependent intensity drift. The output is a two-dimensional feature abundance table with median RT and m/z coordinates and normalized intensities, requiring no user-specified RT tolerance, mass tolerance, or smoothing parameters. This zero-parameter design ensures reproducible signal detection even in the absence of QC samples or reference standards.
## Related tools
- **mzLearn** (Primary signal detection and RT/m/z drift correction engine; autonomously learns signal characteristics and iteratively refines alignment without user parameters) — github.com/ReviveMed/mzEmbed
- **mzEmbed** (Framework that integrates mzLearn outputs (aligned feature matrices) for downstream pre-trained generative model development and fine-tuning) — github.com/ReviveMed/mzEmbed
## Examples
```
python -m mz_learn.run_signal_detection --input_dir /path/to/raw_mzml_files --output_csv /path/to/feature_table.csv
```
## Evaluation signals
- Output feature table has shape [n_samples, n_features] with no missing values in RT or m/z columns; all intensities are normalized (e.g., z-scored or log-transformed with consistent mean and variance across samples).
- Retention time distribution across samples for the same m/z feature shows reduced variance post-correction compared to raw data; RT drift (linear or systematic shift across run order) is eliminated.
- Mass accuracy is preserved: m/z values remain within the instrument's typical accuracy range (e.g., <5 ppm for Orbitrap, <10 ppm for Q-TOF); no systematic m/z shift as a function of sample index or batch.
- Feature reproducibility: the same metabolite signal is detected across replicate or similar biological samples at consistent RT and m/z, with intensity variation explained by biological differences rather than instrumental drift.
- Output is compatible with downstream mzEmbed pretraining pipeline: feature matrix shape is [n_samples, feature_count] with no null entries, and intensity values are numeric and normalized.
## Limitations
- Zero-parameter design assumes sufficient sample diversity and cohort size (tested at 2,075 files) to learn robust signal characteristics; very small or homogeneous cohorts may produce suboptimal alignment.
- Iterative learning depends on stable instrument performance; extreme instrumental malfunction or calibration failure during a run may introduce artifacts that mzLearn cannot correct without explicit user intervention.
- Output is a 2D feature table and does not include ion mobility, fragment spectra, or other orthogonal dimensions; multi-dimensional data (e.g., LC–IMS–MS) would require custom preprocessing.
- No built-in metabolite annotation or MS/MS spectral matching; the feature table must be passed to downstream annotation tools for compound identification.
## Evidence
- [readme] mzLearn is a data-driven algorithm designed to autonomously detect metabolite signals from raw LC/MS data without requiring input parameters from the user.: "mzLearn is a data-driven algorithm designed to autonomously detect metabolite signals from raw LC/MS data without requiring input parameters from the user."
- [readme] iteratively learning signal characteristics to ensure high-quality signal detection: "iteratively learning signal characteristics to ensure high-quality signal detection"
- [readme] mzLearn autonomously refines signal detection, correcting for retention time (rt) and intensity drifts caused by batch effects and run order.: "mzLearn autonomously refines signal detection, correcting for retention time (rt) and intensity drifts caused by batch effects and run order."
- [readme] A two-dimensional table of detected features defined by median rt and m/z values, with normalized intensities across samples.: "A two-dimensional table of detected features defined by median rt and m/z values, with normalized intensities across samples."
- [readme] Capable of handling large-scale datasets (e.g., 2,075 files in a single run).: "Capable of handling large-scale datasets (e.g., 2,075 files in a single run)."
- [other] Apply the data-driven signal detection algorithm to identify peaks and features across the mass-to-charge and retention time dimensions without requiring manual parameter optimization.: "Apply the data-driven signal detection algorithm to identify peaks and features across the mass-to-charge and retention time dimensions without requiring manual parameter optimization."
Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.