Use when when you have processed authentic standards with LC-MS in positive and negative ESI modes, converted results to .mzML format, and need to build a validated in-house reference library with MS1 m/z and RT measurements for use in untargeted metabolomics compound identification workflows.
Scanned 9/12/2026
Install to Claude Code
npx -y skills add HolobiomicsLab/asb-skill-collections --skill metabolite-library-curation-ms1-rt --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of Metabolite Library Curation Ms1 Rt?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/holobiomicslab-metabolite-library-curation-ms1-rt-asb-skill-collections)More formats (shields.io, HTML) on the badges page.
---
name: metabolite-library-curation-ms1-rt
description: Use when when you have processed authentic standards with LC-MS in positive and negative ESI modes, converted results to .mzML format, and need to build a validated in-house reference library with MS1 m/z and RT measurements for use in untargeted metabolomics compound identification workflows.
license: CC-BY-4.0
metadata:
edam_operation: http://edamontology.org/operation_3802
edam_topics:
- http://edamontology.org/topic_3172
- http://edamontology.org/topic_0121
tools:
- metScribeR
- R
- chromatographR
- mzR
- Shiny
- MSConvert
techniques:
- LC-MS
derived_from:
- doi: 10.1021/acs.jproteome.5c00548
title: metScribeR
evidence_spans:
- This package provides an automated workflow for processing in-house metabolite library standards data
- This package... can be launched using a function exported by this package
- can be launched using a function exported by this package
claims: []
provenance:
collection: https://w3id.org/holobiomicslab/asb-skill/collection/metabolomics/v2
assembled_by: scripts/collect_metabolomics_collection.py
sources:
- build: coll_metscriber_cq
doi: 10.1021/acs.jproteome.5c00548
title: metScribeR
dedup_kept_from: coll_metscriber_cq
schema_version: 0.2.0
attribution:
generator: AgenticScienceBuilder
original_doi: 10.1021/acs.jproteome.5c00548
all_source_dois:
- 10.1021/acs.jproteome.5c00548
zenodo_doi: 10.5281/zenodo.20794027
curators: []
promoter: Louis-Félix Nothias
sponsor: CNRS & Université Côte d'Azur
---
# metabolite-library-curation-ms1-rt
## Summary
Automated curation of in-house metabolite reference libraries using MS1 m/z and retention time (RT) data from LC-MS standards via the metScribeR package and interactive Shiny interface. This skill enables construction of curated metabolite libraries for untargeted metabolomics without requiring MS2 data.
## When to use
When you have processed authentic standards with LC-MS in positive and negative ESI modes, converted results to .mzML format, and need to build a validated in-house reference library with MS1 m/z and RT measurements for use in untargeted metabolomics compound identification workflows.
## When NOT to use
- If you lack mzML files or monoisotopic mass values for your standards.
- If your goal is to annotate experimental samples without first validating authentic standard peaks; library curation must precede experimental compound identification.
- If you have only MS2 fragmentation data without MS1 m/z or RT measurements; metScribeR explicitly does not use MS2 for library building.
## Inputs
- mzML files (positive and negative ESI mode LC-MS analyses of authentic standards)
- standards_df.csv or .tsv (common_name, monoisotopic_mass, pos_mode_mzML_file_path, neg_mode_mzML_file_path, optional: inchiKey, additional_identifiers)
- adduct_df.csv or .tsv (adduct, change_from_neutral, mode)
## Outputs
- exported_metScribeR_library.csv (primary library with all 'good' adducts and MS1/RT data)
- exported_metScribeR_library_with_metrics.csv (all peak classifications and RT assignment metrics)
- exported_metScribeR_MoNA_MSMS.csv (optional MS/MS spectra from MoNA)
- storage_object.RDS (saved workflow state for resumption)
- Figures directory (PNG visualizations of each manually reviewed peak)
## How to apply
Prepare a standards_df.csv file with required columns (common_name, monoisotopic_mass, pos_mode_mzML_file_path, neg_mode_mzML_file_path) and an adduct_df.csv file (adduct, change_from_neutral, mode). Launch metScribeR Shiny app, upload both CSV files, set noise level threshold from the noise plot, and configure m/z and RT tolerances based on your LC-MS equipment resolution. Execute initial peak finding, then manually review each peak in the 'Review Results' tab to classify as 'Good Peak', 'Bad Peak', or 'Multimodal/Indeterminate'. Update the library and optionally check for crossed adducts and query MassBank of North America (MoNA) for MS/MS enrichment. Export the final library as .csv for downstream identification workflows.
## Related tools
- **metScribeR** (Primary package providing automated workflow for MS1/RT library curation and interactive Shiny interface for peak review and library export) — https://github.com/ncats/metScribeR
- **chromatographR** (Dependency for chromatographic data processing in metScribeR) — https://github.com/ethanbass/chromatographR
- **mzR** (Bioconductor package for reading mzML mass spectrometry files)
- **Shiny** (Interactive R web interface for visual inspection, peak filtering, manual review, and library export)
- **MSConvert** (External tool to convert various mass spectrometry data formats to .mzML)
## Examples
```
library(metScribeR); setwd('path/to/example_data'); runMetScribeRShinyApp()
```
## Evaluation signals
- Exported library .csv contains entries only for peaks manually classified as 'Good Peak', with non-missing values for common_name, monoisotopic_mass, MS1 m/z, and RT.
- Peak boundaries (blue and red vertical lines in Review Results tab figures) align with visually distinct chromatographic signals without spillover into adjacent peaks.
- Noise level threshold is set below background signal, as verified by the noise plot figure; all MS observations below this threshold are excluded.
- m/z and RT tolerances used for EIC extraction and adduct discrimination match the specified resolution of the LC-MS instrument and are consistent across all peaks.
- Optional MoNA MS/MS enrichment and crossed adduct checks complete without errors and add valid MS/MS spectra or confidence flags to the exported library.
## Limitations
- Workflow requires authentic chemical standards processed in both positive and negative ESI modes; unavailable or missing mzML files will cause errors.
- Manual peak review step is labor-intensive; computation time for large submissions (e.g., 12,000 mzML files) may exceed 30 minutes.
- MS/MS enrichment from MoNA is dependent on MoNA server speed and may be slow; inchiKey must be provided in standards_df.csv for this feature.
- Library building does not use MS2 data, so structural confirmation is limited; MS/MS is optional and sourced only from external MoNA database.
- Peak filtering and classification decisions (noise threshold, m/z/RT tolerance, peak quality assessment) are user-dependent and require domain knowledge of the LC-MS method.
## Evidence
- [readme] Core workflow purpose: "This package provides an automated workflow for processing in-house metabolite library standards data for use in untargeted metabolomics identification workflows."
- [readme] MS1/RT focus, MS2 exclusion: "metScribeR focuses library building on MS1 & RT data, and MS2 data is not used or required for library construction."
- [readme] Required input files and columns: "Create standards_df.csv (or .tsv) with the following required, identically spelled column names: common_name, with the name of each standard; monoisotopic_mass, the neutral mass of each standard;"
- [readme] Adduct configuration file specification: "Create adduct_df.csv (or .tsv) with the following columns: adduct, with the name of each adduct; change_from_neutral, with the difference between the adduct and its neutral mass; and mode, with"
- [readme] Parameter tuning rationale: "choose an m/z and RT tolerance for creating EICs and distinguishing between adducts. These tolerances should be set based on the ability for the LC-MS equipment to confidently separate two signals."
- [readme] Manual review classification: "Click Good Peak, Bad Peak, and Multimodal/Indeterminate to indicate your confidence in the quality of the peak for inclusion in the final library."
- [readme] Optional MS/MS enrichment: "If desired, use the check for crossed adducts and search MoNA for MS/MS data buttons to add internal identification probability and MS/MS data to the exported results."
- [readme] Output library format and content: "The exported_metScribeR_library.csv file is the primary library including all 'good' adducts and information relevant for making identifications with your new library."
Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.