Use when when you have raw or processed FT-ICR MS peak-abundance .
Scanned 9/12/2026
Install to Claude Code
npx -y skills add HolobiomicsLab/asb-skill-collections --skill ft-icr-ms-data-preprocessing-and-quality-control --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of Ft Icr Ms Data Preprocessing And Quality Control?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/holobiomicslab-ft-icr-ms-data-preprocessing-and-quality-control-d5fe1200)More formats (shields.io, HTML) on the badges page.
---
name: ft-icr-ms-data-preprocessing-and-quality-control
description: Use when when you have raw or processed FT-ICR MS peak-abundance .
license: CC-BY-4.0
metadata:
edam_operation: http://edamontology.org/operation_3695
edam_topics:
- http://edamontology.org/topic_0625
- http://edamontology.org/topic_3375
tools:
- MetaboDirect
- Python 3.8
- R 4.0.2
- NumPy
- pandas
- seaborn
- matplotlib
- vegan
- SYNCSA
- R vegan
- Cytoscape FileTransfer
techniques:
- LC-MS
derived_from:
- doi: 10.1186/s40168-023-01476-3
title: MetaboDirect
evidence_spans:
- The MetaboDirect pipeline was developed in Python 3.8 [38] and R 4.0.2 [39]
- develop MetaboDirect, an open‑source, command‑line‑based pipeline for the analysis (e.g., chemodiversity analysis, multivariate statistics)
- The MetaboDirect pipeline was developed in Python 3.8
- The MetaboDirect pipeline was developed in Python 3.8 [38] and R 4.0.2
- It requires the Python dependencies NumPy
- It requires the Python dependencies NumPy [40], pandas
claims: []
provenance:
collection: https://w3id.org/holobiomicslab/asb-skill/collection/metabolomics/v2
assembled_by: scripts/collect_metabolomics_collection.py
sources:
- build: coll_metabodirect
doi: 10.1186/s40168-023-01476-3
title: MetaboDirect
dedup_kept_from: coll_metabodirect
schema_version: 0.2.0
attribution:
generator: AgenticScienceBuilder
original_doi: 10.1186/s40168-023-01476-3
all_source_dois:
- 10.1186/s40168-023-01476-3
zenodo_doi: 10.5281/zenodo.20794027
curators: []
promoter: Louis-Félix Nothias
sponsor: CNRS & Université Côte d'Azur
---
# ft-icr-ms-data-preprocessing-and-quality-control
## Summary
Automated preprocessing and quality control of direct injection FT-ICR MS data prior to downstream analysis, involving peak detection filtering, isotope removal, mass accuracy validation, and intensity normalization to produce analysis-ready molecular abundance matrices.
## When to use
When you have raw or processed FT-ICR MS peak-abundance .csv files with assigned molecular formulas (m/z values, elemental composition, measured abundance across samples) and need to remove noise, isotopic artifacts, and low-confidence assignments before multivariate or chemodiversity analysis.
## When NOT to use
- Input is raw FT-ICR MS spectral data (uncalibrated .raw or .ms files): MetaboDirect requires pre-processed peak lists with assigned molecular formulas; it does not provide raw spectra preprocessing.
- Peak abundance matrix already curated, normalized, and validated by external QC software: applying redundant filtering may remove true biological signal.
- Analysis goal requires retention of isotopic ratios (13C/12C) for abundance quantitation: isotope filtering will eliminate needed data.
## Inputs
- peak-abundance .csv files (rows=peaks/m/z values, columns=samples, values=measured abundance)
- assigned molecular formula data (elemental composition C/H/O/N/S counts, calculated m/z, assignment error)
- sample metadata (optional: for threshold-based filtering)
- user-defined filtering parameters (m/z range, isotope filter flag, ppm error threshold, sample presence minimum)
## Outputs
- filtered peak-by-sample abundance matrix (.csv)
- peak metadata table with compound class assignments (.csv)
- data quality diagnostic plots (distribution of peaks retained/removed, mass accuracy histogram)
- normalized intensity matrix ready for multivariate analysis
## How to apply
The MetaboDirect pipeline applies sequential filtering to detected peaks: (1) filter by m/z range to exclude out-of-range ions; (2) remove 13C isotopic peaks to reduce redundancy; (3) apply strict mass accuracy threshold (0.5 ppm error in formula assignment) to exclude poor-quality assignments; (4) filter peaks by sample presence using a user-defined threshold (e.g., present in ≥ N samples) to remove rare, likely spurious peaks; (5) determine compound classes (e.g., CHO, CHON, CHONS) for each retained peak based on assigned molecular formula; (6) normalize peak intensities across samples using appropriate normalization method. These steps are executed automatically via a single command-line invocation, producing a curated peak-by-sample abundance matrix and metadata table ready for downstream analysis.
## Related tools
- **MetaboDirect** (Command-line pipeline orchestrating automated peak filtering, isotope removal, formula validation, normalization, and compound class assignment) — https://github.com/Coayala/MetaboDirect
- **NumPy** (Underlying numerical array operations for peak intensity normalization and matrix manipulation)
- **pandas** (Tabular data manipulation and filtering by sample presence, m/z range, and error thresholds)
- **R vegan** (Statistical normalization methods (e.g., Hellinger, log-ratio) applied during intensity normalization step)
- **Cytoscape FileTransfer** (Optional: export and visualization of filtered molecular networks for quality assessment)
## Examples
```
metabodirect -i peak_abundance.csv -mf molecular_formulas.csv -o output_dir --m_z_min 100 --m_z_max 900 --ppm_error 0.5 --remove_isotopes --sample_presence_min 2 --normalization_method hellinger
```
## Evaluation signals
- Output abundance matrix dimensions (rows × samples) match expected retained peak count after filtering thresholds applied; no NaN or negative values present.
- Mass accuracy distribution of retained peaks is centered near 0 ppm with all peaks within ±0.5 ppm error threshold; no peaks from rejected formula assignments appear in output.
- Isotope removal verified: 13C peaks absent from output; 12C counterparts present with expected natural abundance ratios in independent validation dataset.
- Normalized intensities scale consistently across samples (e.g., sum of intensities per sample should be similar or follow expected distributional assumption such as lognormal); before-and-after histograms show transition from skewed to normalized distribution.
- Diagnostic QC plots (e.g., peak retention counts, ppm error distribution, sample presence histogram) match user-supplied filter parameters and show expected filtering outcomes.
## Limitations
- MetaboDirect does not provide raw spectra data preprocessing; input must be pre-processed by external signal-processing software (e.g., CoreMS, Formularity) to produce peak lists and assigned molecular formulas.
- Filtering thresholds (m/z range, ppm error, sample presence minimum, normalization method) are user-defined; no guidance provided for threshold selection specific to instrument, ionization mode, or biological context; suboptimal thresholds may remove true signal or retain noise.
- Isotope filtering assumes clean 13C peak assignment; if formula assignment errors are high, 13C filtering may incorrectly retain artifacts or remove true 13C isotopologues.
- Single-sample datasets or datasets with highly sparse peaks across samples may be adversely affected by stringent 'sample presence' filtering; no automatic adaptive threshold suggested.
- No explicit handling of ion suppression artifacts or signal enhancement bias documented in the article; filtering operates on post-ionization peaks without chemical context correction.
## Evidence
- [methods] detected peaks are filtered by their m/z values: "detected peaks are filtered by their m/z values"
- [methods] isotopic presence (13C peaks): "isotopic presence (13C peaks)"
- [methods] error in formula assignment (0.5 ppm): "error in formula assignment (0.5 ppm)"
- [methods] filtering by number of samples present: "based on the number of samples that they are present in (threshold determined by the user)"
- [methods] Compound classes determination and peak intensity normalization: "Compound classes of each of the filtered peaks are then determined based on the assigned molecular formula. ... peak intensities are normalized in this step"
- [abstract] Single command-line invocation: "MetaboDirect is superior in that it requires a single line of code to launch a fully automated framework"
- [intro] Pipeline accepts processed peak and formula data, not raw spectra: "The pipeline accepts peak abundance and assigned molecular formula data produced after an initial processing of raw FT-ICR MS spectra"
- [methods] MetaboDirect does not provide raw spectra preprocessing: "MetaboDirect does not provide raw spectra data preprocessing"
- [intro] Signal processing background: ion suppression and enhancement confound analysis: "signal suppression or enhancement that can confound downstream data analysis due to ion suppression"
Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.