Use when you have computed empirical p-values from randomized sampling (e.
Scanned 9/12/2026
Install to Claude Code
npx -y skills add HolobiomicsLab/asb-skill-collections --skill fdr-correction-multiple-testing --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of Fdr Correction Multiple Testing?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/holobiomicslab-fdr-correction-multiple-testing)More formats (shields.io, HTML) on the badges page.
---
name: fdr-correction-multiple-testing
description: Use when you have computed empirical p-values from randomized sampling (e.
license: CC-BY-4.0
metadata:
edam_operation: http://edamontology.org/operation_3799
edam_topics:
- http://edamontology.org/topic_0602
- http://edamontology.org/topic_3318
- http://edamontology.org/topic_2269
tools:
- COBRApy
- scipy.stats
- 'INTEGRATE pipeline (Step 10: concordanceAnalysis.py)'
derived_from:
- doi: 10.1371/journal.pcbi.1009337
title: INTEGRATE
evidence_spans: []
claims: []
provenance:
collection: https://w3id.org/holobiomicslab/asb-skill/collection/metabolomics/v1
assembled_by: scripts/collect_metabolomics_collection.py
sources:
- build: coll_integrate
doi: 10.1371/journal.pcbi.1009337
title: INTEGRATE
dedup_kept_from: coll_integrate
schema_version: 0.2.0
---
# FDR correction for multiple testing
## Summary
Apply Benjamini–Hochberg false discovery rate correction to empirical p-values derived from randomized sampling to control Type I error across reaction-level regulatory classifications. This ensures that significance thresholds account for the multiple hypothesis tests performed on thousands of metabolic reactions.
## When to use
You have computed empirical p-values from randomized sampling (e.g., via resampling of RPS scores or Mann–Whitney U tests across multiple reaction-level comparisons) and need to set a single, multiple-testing-corrected significance threshold that applies uniformly across all reactions in a metabolic network. Use this when the number of reactions tested is large (>100) and you want to control genome-scale false discovery rather than per-reaction type I error.
## When NOT to use
- Input is a small number of reactions (< 20 total tested) where Benjamini–Hochberg correction may be overly conservative and Bonferroni or no correction is more appropriate.
- P-values are not empirically derived or do not have a clear null distribution (e.g., analytical p-values without resampling support).
- You are testing a single reaction in isolation or performing post-hoc hypothesis testing on a pre-selected subset of reactions, where FDR correction designed for genome-scale testing is inappropriate.
## Inputs
- empirical p-values (one per metabolic reaction, derived from randomized sampling or Mann–Whitney U tests)
- reaction identifiers (SBML reaction IDs, e.g. 'ACONT', 'PFK')
- Cohen's kappa concordance coefficients (RASvsFFD, RPSvsFFD, RPSvsRAS)
## Outputs
- FDR-adjusted p-values (one per reaction)
- significance assignment (binary: pass/fail at FDR < 0.05)
- filtered reaction classification table (only reactions meeting FDR threshold)
- summary statistics (number and fraction of reactions retained after correction)
## How to apply
After computing empirical p-values for each reaction (e.g., from randomized RPS sampling or Mann–Whitney U tests on flux distributions), apply the Benjamini–Hochberg procedure: rank p-values in ascending order, compute adjusted p-values using the formula p_adj = p × (m / rank), where m is the total number of reactions tested, then filter to retain only reactions with FDR-adjusted p-value < 0.05 (or your chosen alpha). This correction is applied before classifying reactions into regulatory categories (combined, metabolic-only, transcriptional-only, or unclassified) to ensure that only statistically robust concordance signatures are assigned a regulatory class. Document the number of reactions passing the FDR threshold and compare to unadjusted counts to assess the stringency of the correction.
## Related tools
- **COBRApy** (constraint-based sampling and reaction enumeration for multi-hypothesis testing context) — https://github.com/opencobra/cobrapy
- **scipy.stats** (empirical p-value computation and statistical testing (Mann–Whitney U, t-test)) — https://scipy.org/
- **INTEGRATE pipeline (Step 10: concordanceAnalysis.py)** (implementation of FDR correction on Cohen's kappa p-values and regulatory classification) — https://github.com/qLSLab/integrate
## Examples
```
python pipeline/concordanceAnalysis.py --valLog 1.2 --weight linear --resultsMetabolomicFile resultsMetabolomic --meansFile medie_Met.csv
```
## Evaluation signals
- Adjusted p-values are monotonically increasing with rank (no inversions); all adjusted p-values ≥ corresponding unadjusted p-values.
- Number of reactions passing FDR < 0.05 threshold is smaller than number passing unadjusted p < 0.05; document fold-change in stringency.
- Comparison of regulatory classifications before and after FDR correction shows removal of low-concordance reactions; check that concordance metrics (Cohen's kappa) for passing reactions are elevated compared to rejected ones.
- Sanity check: for very large m (thousands of reactions), adjusted p-values inflate by factor ≈ m / rank for top hits; verify this relationship holds in output.
- Reproducibility check: re-run with identical input p-values and confirm adjusted p-values are identical and in same order.
## Limitations
- Benjamini–Hochberg assumes independence or positive correlation among tests; violations (e.g., correlated fluxes in tightly coupled reactions) may reduce power or inflate FDR.
- Empirical p-values derived from randomized sampling are subject to Monte Carlo error; use sufficient sample size (typically >1000 samples per cell-line pair) to stabilize adjusted p-values.
- Single global FDR threshold (α = 0.05) may be overly stringent or permissive for reactions with low prior biological plausibility; consider sensitivity analysis or reaction-class-specific thresholds.
- When a reaction substrate is missing from metabolomics measurements, the reaction is omitted from the dataset before FDR correction, potentially biasing results toward metabolically complete pathways.
## Evidence
- [other] Apply Benjamini–Hochberg FDR correction to empirical p-values derived from randomized RPS sampling to set significance threshold at FDR<5%.: "Apply Benjamini–Hochberg FDR correction to empirical p-values derived from randomized RPS sampling to set significance threshold at FDR<5%"
- [other] Compile final classification table with reaction identifiers, Cohen's kappa scores, adjusted p-values, and assigned regulatory class.: "Compile final classification table with reaction identifiers, Cohen's kappa scores, adjusted p-values, and assigned regulatory class"
- [readme] A dataset of concordance analysis (Cohen coefficient and pearson correlation) of RPS vs RAS, RPS vs FFD, RPS vs FFD, the pvalues and the adjusted pvalues: "A dataset of concordance analysis (Cohen coefficient and pearson correlation) of RPS vs RAS, RPS vs FFD, RPS vs FFD, the pvalues and the adjusted pvalues"
- [other] If one single reaction substrate is missing from the metabolomics measurements, the reaction is omitted from the dataset: "If one single reaction substrate is missing from the metabolomics measurements, the reaction is omitted from the dataset"
Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.