A reusable, execution-grade protocol for hydrothermal synthesis of carbon dots (e.g., from citric acid and urea) that enforces a strict 180 °C reaction temperature to prevent PTFE liner deformation and mandates two non-optional 0.22 μm aqueous syringe filtrations — one post-reaction and one post-dialysis — as lab-mandated quality control steps.
Scanned 9/4/2026
Install to Claude Code
npx -y skills add gabrielmoreira/agent-skills-mirror --skill hydrothermal-synthesis-carbon-dots-180c-dual-0-22um-filtration --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of Hydrothermal Synthesis Carbon Dots 180c Dual 0 22um Filtration?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/gabrielmoreira-hydrothermal-synthesis-carbon-dots-180c-dual-0-22u)More formats (shields.io, HTML) on the badges page.
---
id: "45d0ef27-dd75-4fc2-8185-143379827b64"
name: "hydrothermal-synthesis-carbon-dots-180c-dual-0.22um-filtration"
description: "A reusable, execution-grade protocol for hydrothermal synthesis of carbon dots (e.g., from citric acid and urea) that enforces a strict 180 °C reaction temperature to prevent PTFE liner deformation and mandates two non-optional 0.22 μm aqueous syringe filtrations — one post-reaction and one post-dialysis — as lab-mandated quality control steps."
version: "0.1.1"
tags:
- "carbon-dots"
- "hydrothermal-synthesis"
- "lab-protocol"
- "filtration"
- "temperature-safety"
triggers:
- "水热法合成碳点"
- "碳点制备步骤"
- "180度反应釜限制"
- "必须两次0.22微米过滤"
- "柠檬酸尿素体系执行细则"
---
# hydrothermal-synthesis-carbon-dots-180c-dual-0.22um-filtration
A reusable, execution-grade protocol for hydrothermal synthesis of carbon dots (e.g., from citric acid and urea) that enforces a strict 180 °C reaction temperature to prevent PTFE liner deformation and mandates two non-optional 0.22 μm aqueous syringe filtrations — one post-reaction and one post-dialysis — as lab-mandated quality control steps.
## Prompt
# Goal
Generate a fully executable, step-by-step laboratory procedure for hydrothermal synthesis of carbon dots using user-specified precursors (e.g., citric acid + urea), strictly adhering to thermal hardware limits and dual-filtration quality gates.
# Constraints & Style
- Reaction temperature MUST be exactly 180 °C — no higher, no rounding, no approximation; state "180 °C" unambiguously in all references.
- Hold time at 180 °C MUST default to 4 h unless explicitly overridden by user; do not suggest >4 h without confirmation.
- Two mandatory 0.22 μm aqueous-phase syringe filtrations are required: first immediately after cooling and opening the reactor (to remove particulates and PTFE debris), second after dialysis and before final storage (as final sterility/purity gate).
- Specify consumables precisely: "0.22 μm hydrophilic PVDF syringe filter", "MWCO 500 Da cellulose ester dialysis tubing", "15 mL polypropylene centrifuge tube", "brown glass HPLC vial for storage".
- Include operator actions verbatim where critical: "vacuum-filter using a 10 mL glass syringe", "discard first 0.5 mL filtrate", "rinse filter housing with 0.5 mL DI water and collect rinse in same vial", "label vial with: 'CDs-<YYYYMMDD>-BATCH#-F2'".
- Never omit unit symbols (e.g., always write "180 °C", "4 h", "0.22 μm", "15 mL") or use ambiguous terms like "room temperature" — instead write "22–25 °C (ambient lab condition)".
- Do NOT recommend alternatives to either mandated filtration (e.g., no centrifugation-only substitution, no single-filter shortcuts).
- Use imperative mood, second-person present tense (e.g., "Weigh", "Transfer", "Filter", "Label").
- Assume deionized water (≥18.2 MΩ·cm) and standard lab equipment unless otherwise specified.
- Output plain Markdown with clear section headers (## Step 1, ## Step 2…); no bullet-point nesting beyond one level; no emojis or decorative symbols.
# Workflow
1. Weigh and dissolve precursors in exact masses and volume.
2. Load into PTFE liner; seal reactor; heat to exactly 180 °C; hold for exactly 4 h; cool passively ≥6 h.
3. Open reactor; transfer crude solution to a 15 mL PP tube; vacuum-filter through 0.22 μm PVDF syringe filter into a new tube; discard first 0.5 mL; collect remaining filtrate as "pre-dialysis filtrate".
4. Load pre-dialysis filtrate into MWCO 500 Da dialysis bag; dialyze against 2 L DI water with 6 scheduled water changes (at 6/12/18/24/30/36 h); total dialysis duration = 36 h.
5. Retrieve dialysate; filter again through an identical 0.22 μm PVDF syringe filter into a pre-labeled brown glass vial; rinse filter housing; pool rinse with main filtrate.
6. Store vial at 4 °C in dark; annotate label with date, batch ID, and "F2" (denoting two filtrations).
## Triggers
- 水热法合成碳点
- 碳点制备步骤
- 180度反应釜限制
- 必须两次0.22微米过滤
- 柠檬酸尿素体系执行细则
Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.
No comments yet. Be the first to comment!