Catalog of every configuration axis in Plenum — config.yaml add-on options, run.sh/backend environment variables, system_settings DB keys, ThermostatConfig fields, per-room settings, schedule/override fields — with defaults, units, validation guards, and UI location. Load when you need to know where a setting lives, what its default/bounds are, whether a value is stored in °F or as a delta, or when adding a new knob (config option, temperature field, or system flag) and need the parity checkl...
Scanned 9/11/2026
Install to Claude Code
npx -y skills add dhruvb14/smart-thermostat-with-vents --skill plenum-config-and-flags --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of Plenum Config And Flags?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/dhruvb14-plenum-config-and-flags)More formats (shields.io, HTML) on the badges page.
---
name: plenum-config-and-flags
description: Catalog of every configuration axis in Plenum — config.yaml add-on options, run.sh/backend environment variables, system_settings DB keys, ThermostatConfig fields, per-room settings, schedule/override fields — with defaults, units, validation guards, and UI location. Load when you need to know where a setting lives, what its default/bounds are, whether a value is stored in °F or as a delta, or when adding a new knob (config option, temperature field, or system flag) and need the parity checklist.
---
# Plenum configuration and flags
Every tunable in Plenum, layer by layer, with where it is stored, its default,
its guard, and where the user reaches it. All facts verified against the repo
at v0.35.0 (2026-09). Trust these tables only after running the re-verification
one-liners in Provenance if the repo has moved.
**When NOT to use this skill**
- How to *run* the add-on / docker / ports / backup → `plenum-run-and-operate`.
- WHY a guard exists (deadband physics, short-cycling, dead-heading) → `hvac-zoning-reference`.
- What CI gates a change must clear before merging a new knob → `plenum-change-control`.
- The #231 write-boundary conversion contract itself → `plenum-architecture-contract` (one-liner here: frontend sends raw display values; the backend converts at the write boundary via `to_f`/`delta_to_f`).
**Jargon used below**
- *absolute* temp: a real temperature; °C→°F uses `*9/5 + 32`.
- *delta* temp: a difference (deadband, offset); °C→°F uses `*9/5` only — no 32 offset. Mixing these silently corrupts data.
- *deadband*: ±°F tolerance within which a room counts as "at target".
- *overshoot*: how far past the most demanding room's target the thermostat is set to keep the HVAC running.
- *holdover*: how long a presence-activated room stays active after last motion.
**The universal invariant**: every temperature is stored in °F in SQLite.
Conversion helpers live in `smart_vent/backend/units.py` (`to_f`, `delta_to_f`,
`from_f`, `from_f_delta`); `routes.py` imports them as `_to_f` etc. (CLAUDE.md
was corrected 2026-07-05 to say so — the import aliases are in routes.py, the
implementations in `units.py`.) Validation bounds are applied **after**
normalization to °F, per the lesson recorded in `.jules/sentinel.md`
(2026-05-05): validating the raw input before conversion is meaningless when
the unit varies. The canonical band for user-facing targets is **40–90 °F on
the internal °F value**; setpoint clamps get 40–100 °F (verified in code, see
tables).
---
## Layer 1 — Add-on options (`smart_vent/config.yaml` → `run.sh`)
Stored by the HA Supervisor in `/data/options.json`; read by `run.sh` via
`bashio::config` with an uppercase-env-var fallback for plain Docker (helper
`get_config` in `run.sh`). Parity between `config.yaml` `options:` and `run.sh`
is enforced by `smart_vent/backend/tests/test_addon_config.py`.
| Option | Schema | Default | Exported as | Notes |
|---|---|---|---|---|
| `ha_url` | str | `""` | `HA_URL` | Blank + supervisor → `http://supervisor/core`; blank + no supervisor → `http://homeassistant.local:8123` |
| `ha_token` | str | `""` | `HA_TOKEN` | Blank → `SUPERVISOR_TOKEN` when available |
| `use_wss` | bool | `false` | `HA_USE_WSS` | truthy set: `1/true/yes` (parsed in `ha_client.py`) |
| `ssl_verify` | bool | `true` | `HA_SSL_VERIFY` | |
| `timezone` | str | `"America/New_York"` (config.yaml) / `UTC` (run.sh fallback) | `TZ` | Drives schedule evaluation (`backend/tz.py` reads `TZ`) |
| `temperature_unit` | str | `""` (auto-detect) | `TEMPERATURE_UNIT` | Non-empty `F`/`C` is a **hard override lock** in the scheduler; blank lets HA `/api/config` + last-known DB value decide. Do not default to `F` (#281) |
| `require_auth` | bool | `true` | `REQUIRE_AUTH` | Auth campaign (#373), **shipped**. Gates the direct ports 8099/9099 only — HA ingress is always trusted regardless. `true` = direct-port UI needs an HA-account login, MCP needs a minted bearer token; `false` = legacy fully-open ports. See `backend/auth.py`. |
| `oidc_configuration_url` | str | `""` | `OIDC_CONFIGURATION_URL` | OIDC SSO (#464), **shipped**, optional. Web UI only — MCP keeps bearer tokens. All four of `oidc_configuration_url`/`oidc_client_id`/`oidc_client_secret`/`plenum_external_url` must be set for the "Sign in with …" button to replace HA password login. |
| `oidc_client_id` | str | `""` | `OIDC_CLIENT_ID` | See above |
| `oidc_client_secret` | password | `""` | `OIDC_CLIENT_SECRET` | See above; never logged |
| `oidc_scopes` | str | `"openid email profile"` | `OIDC_SCOPES` | Must include `openid` |
| `oidc_allowed_users_glob` | str | `"*"` | `OIDC_ALLOWED_USERS_GLOB` | Glob over email/username; `"*"` = anyone the IdP authenticates |
| `oidc_provider_name` | str | `""` | `OIDC_PROVIDER_NAME` | Label for the sign-in button, e.g. "Authelia"; falls back to `"SSO"` in `oidc.py` when blank |
| `plenum_external_url` | str | `""` | `PLENUM_EXTERNAL_URL` | Public base URL; redirect URI is `<plenum_external_url>/api/auth/oidc/callback` |
| `mqtt_host` | str | `""` | `MQTT_HOST` | MQTT bridge (#519), **shipped**, all-optional. Blank + Supervisor → broker auto-discovered via `services: mqtt:want`; blank + no Supervisor → bridge stays unconfigured (`MqttConfig.configured` is False). |
| `mqtt_port` | int | `1883` | `MQTT_PORT` | |
| `mqtt_user` | str | `""` | `MQTT_USER` | |
| `mqtt_password` | password | `""` | `MQTT_PASSWORD` | |
| `mqtt_discovery` | bool | `true` | `MQTT_DISCOVERY` | Publish HA MQTT Discovery configs so every control appears as a native HA entity |
| `mqtt_discovery_prefix` | str | `"homeassistant"` | `MQTT_DISCOVERY_PREFIX` | Must match the HA MQTT integration's discovery prefix |
| `mqtt_topic_prefix` | str | `""` | `MQTT_TOPIC_PREFIX` | Blank → Supervisor-resolved add-on slug (`plenum` / `plenum_beta`) via `/addons/self/info`; standalone Docker with no slug falls back to hardcoded `"plenum"` (collides if two containers share one broker — set this to avoid it) |
Ports/manifest facts (config.yaml): ingress on **8099**, MCP on **9099**
(both host-ports optional/blank by default), `DATA_DIR: /config` via the
`environment:` block, `map: [data, addon_config:rw]`, `services: [mqtt:want]`
(soft-requests the Supervisor's built-in MQTT broker; add-on still starts with
none). `run.sh` one-time migrates `flair.db`/`app.db` from `/data` to
`$DATA_DIR`. `CI=true` makes `run.sh` self-kill after 10 s (smoke test).
Both `require_auth` and every MQTT/OIDC option are **deployment-time config
only** — turning the *MCP server* or the *MQTT bridge* on/off day-to-day is a
separate runtime toggle in `system_settings` (`mcp_enabled` / `mqtt_enabled`,
Layer 3): the add-on options above configure *how* they'd connect, the
Settings-page switches decide *whether* they do right now.
## Layer 2 — Environment variables the backend reads
Grep-verified across `smart_vent/backend/` (excluding tests):
| Env var | Read in | Default | Purpose |
|---|---|---|---|
| `DATA_DIR` | `main.py`, `mcp_server.py` | `/data` (backend) — but `run.sh` exports `/config` | SQLite `app.db` location |
| `PORT` | `main.py` | `8099` | Web UI / API port |
| `MCP_PORT` | `main.py` | `9099` | HTTP MCP server port |
| `HA_URL`, `HA_TOKEN` | `ha_client.py`, `mcp_tools/ha_entities.py` | see Layer 1 | HA WebSocket/REST auth |
| `SUPERVISOR_TOKEN` | `ha_client.py` | — | Injected by HA supervisor |
| `HA_USE_WSS` | `ha_client.py` | `false` | `wss://` vs `ws://` |
| `HA_SSL_VERIFY` | `ha_client.py` | `true` | TLS verification |
| `TZ` | `tz.py` | — | Local timezone for schedules |
| `TEMPERATURE_UNIT` | `scheduler.py` (`_unit_override`) | `""` | Unit override lock (see Layer 1) |
| `REQUIRE_AUTH` | `main.py` (`_resolve_require_auth`) | `""` → **`False`** when unset | Unset (plain local dev / pytest, which never run `run.sh`) means auth off, matching pre-#373 behavior; any real deployment goes through `run.sh`, which always exports it (default `"true"`). An unrecognized non-empty value (e.g. a typo) makes the process `SystemExit` rather than fail open (#499) |
| `OIDC_CONFIGURATION_URL`, `OIDC_CLIENT_ID`, `OIDC_CLIENT_SECRET`, `OIDC_SCOPES`, `OIDC_ALLOWED_USERS_GLOB`, `OIDC_PROVIDER_NAME`, `PLENUM_EXTERNAL_URL` | `oidc.py` | see Layer 1 | OIDC SSO (#464) config, read via `oidc.py`'s injectable `env` dict (defaults to `os.environ`) |
| `SUPERVISOR_HOST` | `auth.py` | `"supervisor"` | Hostname to reach the Supervisor on the hassio Docker network; overridable for tests |
| `PLENUM_SESSION_SECRET` | `session.py` | — (falls back to a `0600`-perm file beside the DB) | Base64url signing-key override for session cookies; lets multiple replicas share one key, or an E2E harness pin it. Ignored (with a warning) if not valid base64url |
| `MQTT_HOST`, `MQTT_PORT`, `MQTT_USER`, `MQTT_PASSWORD`, `MQTT_DISCOVERY`, `MQTT_DISCOVERY_PREFIX`, `MQTT_TOPIC_PREFIX` | `mqtt/config.py` | see Layer 1 | MQTT bridge (#519) config |
| `ADDON_SLUG` | `mqtt/config.py` | — | MQTT topic-prefix override; normally resolved from the Supervisor's `/addons/self/info` instead, not set directly except in tests |
| `SUPERVISOR_TOKEN` | `ha_client.py`, `auth.py`, `mqtt/config.py` | — | Injected by HA supervisor; also gates Supervisor-REST lookups (MQTT broker discovery, slug, `resolve_supervisor_ip`) |
| `PLENUM_CLOCK_OVERRIDE` | `tz.py` (`now_utc`, not `now_local`) | — | E2E-stack-only ISO-8601 instant that pins the room active-status read path's "now" for deterministic visual-regression goldens (#456); never set in production, scoped narrowly so it can't stall cycle timing |
| `PLENUM_MCP_STATELESS` | `mcp_http.py` | unset → `True` | Test axis for the MCP SDK's stateless vs. session-ID transport mode; no add-on option or UI, same precedent as `PLENUM_CLOCK_OVERRIDE` |
| `CI` | `run.sh` only | — | Smoke-test self-exit |
Frontend build-time: `VITE_APP_VERSION` — baked from `config.yaml version:`;
the value `"CI"` flips `isCI` in `frontend/src/ci.tsx` (frozen UI for E2E
goldens). Not a runtime knob.
## Layer 3 — `system_settings` DB keys (key/value TEXT table)
Accessors: `db.get_system_setting` / `db.set_system_setting`
(`smart_vent/backend/db.py:3205`). Exhaustive key list (grep-verified;
booleans stored as `"1"`/`"0"`):
| Key | Default | Set by | Read by | UI |
|---|---|---|---|---|
| `temperature_unit` | `"F"` | scheduler startup (env override or HA detect) | scheduler `_active_unit`; everything reads unit via `scheduler.get_temperature_unit()` (sync), never DB directly | `GET /api/settings`; display-only |
| `unit_change_ack_required` | `"0"` | scheduler per-tick `_check_unit_change` | `GET /api/settings` | `UnitChangeBanner`; dismiss `POST /api/settings/ack-unit-change` |
| `unit_change_acked_unit` | `""` | `ack_unit_change()` — records which HA unit was dismissed so the banner doesn't re-raise (#288) | scheduler | none (bookkeeping) |
| `system_enabled` | `"1"` | `POST /api/system/enabled` | engine gate | master toggle in `App.tsx` header |
| `developer_mode` | `"0"` | `POST /api/system/dev-mode` | scheduler + `ha.dev_mode` (suppresses real HA writes) | App header + `DevMode.tsx` page |
| `mcp_enabled` | `"0"` | `POST /api/system/mcp` | MCP ASGI app per-request (returns 503 when off) | App header toggle |
| `mqtt_enabled` | `"0"` | `POST /api/system/mqtt` | MQTT bridge loop per-cycle (connects/disconnects live) | Settings page toggle — runtime twin of `mcp_enabled` (#519); the broker itself is configured via the Layer 1 `mqtt_*` options, this only switches the bridge on |
| `theme` | `"system"` | `POST /api/settings/theme` — must be one of `light`/`dark`/`system` | `App.tsx` (display-only; `"system"` defers to `prefers-color-scheme`) | Settings page (#458) |
| `vacation_mode_enabled` | `"0"` | `POST/DELETE /api/settings/vacation-mode` | scheduler + engine | `VacationModeModal` / `VacationModeBanner` |
| `vacation_mode_return_at` | `""` | same | scheduler `_check_vacation_expiry` (auto-disables past return time) | same; `return_at` required, must be future ISO-8601 |
| `outside_temperature_entity_id` | `""` | `PUT /api/settings/outside-temp-entity` (validates entity exists in HA and is numeric) | cooling lockout (#209), pre-cool (#248), Eco Mode (#404, required before enabling — #524 extended the same requirement to ambient suppression), metrics | `OutsideTempPicker` on Thermostats page |
| `sensor_stale_after_min` | `30.0` (`SENSOR_STALE_AFTER_MIN`, `engine/cycle_engine.py:56`) | `PUT /api/settings/sensor-staleness` — guard **1–1440 min** | engine staleness guard (#211), `/api/sensor-health` | Thermostats page |
| `event_log_retention_days` | `"7"` | `POST /api/settings/log-retention` — one validation pass over the WHOLE body (`_RETENTION_WRITE_FIELDS`) before any write, so a rejected request commits nothing: bools refused (`isinstance(False, int)` is True — #609's defect), non-ints refused, then range-checked `1..db.MAX_RETENTION_DAYS` (36500) | `_purge_old_logs` deletes `event_log` rows past it | Logs → Retention |
| `cycle_log_retention_days` | `"30"` | same pass, same `1..36500` range | **Deletes nothing** (#617). Cycle History *display* window only — `routes._cycle_history_floor`, which never widens past what `metrics_retention_days` actually keeps | Logs → Retention |
| `metrics_retention_days` | `"365"` (`0` = keep forever) | same pass, but the range is `0..36500` — the siblings' floor of 1 would turn keep-forever into keep-one-day, deleting the archive the operator just asked to protect | The **only** setting that deletes `cycle_logs` (+ all four `ON DELETE CASCADE` children: `room_cycle_states`, `cycle_temp_samples`, `cycle_setpoint_history`, `cycle_vent_events`), and the floor `routes._retention_floor` clamps every metrics range to | Logs → Retention |
| `migration_holdover_timestamps_utc_v1` | — | one-shot migration sentinel (#65) | `db.init_db` | none |
| `migration_short_cycle_defaults_v1` | — | one-shot sentinel (#208 backfill: existing thermostats get runtime=10/off=5 min) | `db.init_db` | none |
| `migration_eco_defaults_v1` | — | one-shot sentinel: seeds the seven Eco numeric columns (Layer 4) on pre-existing thermostat rows with round-in-the-active-unit defaults; behaviorally inert — `eco_mode_enabled` stays off | `db.init_db` | none |
| `migration_metrics_retention_v1` | — | one-shot sentinel (#617): seeds `metrics_retention_days` at `max(existing cycle_log_retention_days, 365)`, so an upgrade can only ever preserve MORE data than before. Sentinel-guarded so a later deliberate lowering is not raised back | `db.init_db` | none |
The scheduler caches `system_enabled` / `developer_mode` / `mcp_enabled` /
`mqtt_enabled` / `theme` / vacation state in memory at startup and on
`reload_from_db()`; routes read the cached getters, never the DB.
## Layer 4 — `ThermostatConfig` fields (`smart_vent/backend/models.py`, PK `thermostat_entity_id`)
Written by `POST /api/thermostats` and `PUT /api/thermostats/{entity_id}`;
docs: `docs/thermostat-settings.md`, `docs/safety.md`. UI: Thermostats page
(`SAFETY_FIELDS` loop in `frontend/src/pages/Thermostats.tsx`, `kind:
"absolute_temp" | "delta_temp" | "other"` drives the unit-label suffix).
Numeric safety fields are bounds-checked by `_THERMO_NUMERIC_BOUNDS` in
`routes.py` (#295) — non-numeric or negative values would crash/invert engine
tick arithmetic.
| Field | Default | Unit/kind | Guard (server-side) | Status |
|---|---|---|---|---|
| `name` | `""` | — | — | production |
| `default_temp` | `None` | °F absolute, nullable (fallback presence target) | 40–90 °F post-conversion; null clears | production |
| `min_setpoint` / `max_setpoint` | 60.0 / 85.0 | °F absolute | **40–100 °F** post-conversion; `min < max` | production; hard clamp on every setpoint command |
| `deadband` | 0.5 | °F **delta** | ≥ 0 | production |
| `overshoot_delta` | 2.0 | °F **delta** | ≥ 0 | production |
| `max_vent_closed_min` | 0 (off) | minutes | ≥ 0 | production safety valve |
| `cycle_timeout_hours` | 3.0 | hours | **> 0** (strict; UI input min=0.5) | production safety valve |
| `reconciliation_interval_min` | 0 (off) | minutes | ≥ 0; docs say "should not exceed cycle_timeout×60" but that upper bound is **advisory only — not enforced in code** (engine just skips when ≤0) | production |
| `total_vents_count` | `None` | count (smart + passive registers) | positive int; **required at registration** (#213); null → transitional "≥1 open" fallback + UI banner | production |
| `has_bypass_damper` | `False` | bool | — | production; True disables the airflow floor |
| `min_open_vents_fraction` | 0.333 | fraction | 0 < v ≤ 1 | production; airflow floor = `ceil(total × fraction)` |
| `vacation_hvac_mode` | `"single"` | enum | `"range"` or `"single"` | production |
| `min_cycle_runtime_min` | 0 (off; recommended 10) | minutes | ≥ 0 | production, short-cycle protection (#208) |
| `min_cycle_offtime_min` | 0 (off; recommended 5) | minutes | ≥ 0 | production (#208) |
| `cooling_lockout_below_f` | `None` (off) | °F absolute, nullable | converted via `_to_f`; needs the outside sensor (Layer 3) | production (#209) |
| `overflow_during_min_runtime` | `True` | bool | — | production (#237); auto-off in vacation mode |
| `unavailable_abort_after_min` | 5 | minutes | non-negative int; 0 = never abort (not recommended) | production (#267) |
| `eco_mode_enabled` | `False` | bool | — | production (#404); Eco Mode is outdoor-temperature-compensated setpoint drift, off by default and a no-op on the exact pre-Eco code path when off. Enabling it is rejected server-side without the Layer 3 outside-temp sensor configured |
| `eco_cooling_outdoor_threshold` | 86.0 | °F absolute (outdoor) | −40–130 °F post-conversion (`_ECO_ABS_LO`/`_ECO_ABS_HI`) | production (#404); `docs/eco-mode.md` |
| `eco_cooling_full_drift_temp` | 100.0 | °F absolute (outdoor) | −40–130 °F post-conversion | production (#404) |
| `eco_cooling_max_drift` | 4.0 | °F **delta** | 0–20 °F post-conversion | production (#404) |
| `eco_heating_outdoor_threshold` | 40.0 | °F absolute (outdoor) | −40–130 °F post-conversion | production (#404) |
| `eco_heating_full_drift_temp` | 0.0 | °F absolute (outdoor) | −40–130 °F post-conversion | production (#404) |
| `eco_heating_max_drift` | 4.0 | °F **delta** | 0–20 °F post-conversion | production (#404) |
| `eco_hysteresis_band` | 2.0 | °F **delta** | 0–10 °F post-conversion | production (#404) |
| `eco_suspend_until` | `None` | ISO-8601 UTC string, nullable | — | production (#500); **read-only** on `POST`/`PUT /api/thermostats/…` — lives in its own `eco_suspensions` table, not a `thermostat_configs` column, so a stale form save can never clobber it. Written only via `POST`/`DELETE /api/thermostats/{entity_id}/eco-suspend` |
Existing thermostats registered before Eco Mode shipped were back-filled with
round-in-the-active-unit Eco defaults by the `migration_eco_defaults_v1`
sentinel (Layer 3); `eco_mode_enabled` itself was left off.
## Layer 5 — Per-room settings (`Room` in models.py; Rooms page modal)
| Field | Default | Unit/kind | Guard | Notes |
|---|---|---|---|---|
| `name`, `thermostat_entity_id` | required | — | — | |
| `include_thermostat_sensor` | `False` | bool | — | Count the thermostat's own temp in the room average |
| `system_wide_temp` | `None` | °F absolute, nullable | 40–90 °F post-conversion | The room-level **presence target**; falls back to thermostat `default_temp` (docs/presence.md) |
| `presence_holdover_hours` | 2.0 | hours | 0–8760; **0 disables presence activation for the room** | |
| `temp_offset` | 0.0 | °F **delta** | −20 to +20 °F post-conversion | Post-vent-close drift compensation (#86) |
| `deadband_override` | `None` (inherit thermostat deadband) | °F **delta**, nullable | 0–10 °F post-conversion; null clears (#277) | Affects only this room's start/join-cycle vote |
| `ambient_suppression_enabled` | `False` | bool | — | Pre-cool/pre-heat (#248), `docs/precool-presence.md`; inert without outside sensor |
| `ambient_suppression_mode` | `"any_presence"` | enum | `any_presence` \| `off_schedule_only` | |
| `ambient_suppression_min_differential` | 5.0 | °F **delta** | ≥ 0 | Outside must be this far past target to coast |
| `ambient_suppression_deadband` | 2.0 | °F **delta** | ≥ thermostat deadband **only when feature enabled** | Widened coasting band; engine clamps with `max()` anyway |
| `ambient_suppression_off_schedule_window_min` | 60 | minutes | non-negative int | Only for `off_schedule_only` mode; turning ambient suppression **on** is rejected server-side without the Layer 3 outside-temp sensor configured (#524, same guard pattern as Eco Mode) |
| `eco_mode_enabled` | `None` | tri-state bool, nullable | — | production (#404); `None` inherits the thermostat toggle, `True`/`False` overrides it for this room only |
| `eco_cooling_outdoor_threshold` | `None` | °F absolute (outdoor), nullable | same −40–130 °F band as the thermostat field when set | production (#404); **field-level null-inheritance** — `None` inherits the thermostat's value for just this field, so a room can override one Eco setting while inheriting the rest |
| `eco_cooling_full_drift_temp` | `None` | °F absolute (outdoor), nullable | same −40–130 °F band | production (#404) |
| `eco_cooling_max_drift` | `None` | °F **delta**, nullable | same 0–20 °F band | production (#404) |
| `eco_heating_outdoor_threshold` | `None` | °F absolute (outdoor), nullable | same −40–130 °F band | production (#404) |
| `eco_heating_full_drift_temp` | `None` | °F absolute (outdoor), nullable | same −40–130 °F band | production (#404) |
| `eco_heating_max_drift` | `None` | °F **delta**, nullable | same 0–20 °F band | production (#404) |
| `eco_hysteresis_band` | `None` | °F **delta**, nullable | same 0–10 °F band | production (#404) |
| `notes` | `""` | — | — | |
UI: Thermostats page for the thermostat-level Eco fields, Rooms page modal
for the per-room overrides — same `docs/eco-mode.md`.
Sub-entities: sensors (`sensor.*`), vents (`cover.*` with per-vent
`control_method` ∈ `open_close | set_position | set_tilt_position | toggle`),
presence sensors (`binary_sensor.*`). A room may have **zero vents** —
monitor-only rooms are supported by design (`docs/rooms-and-zones.md`: "Zero
or more vents").
## Layer 6 — Schedules and overrides
**Schedule** (`Schedule` in models.py; Schedules page; `docs/schedules.md`):
`days_of_week` (0=Mon), local `start_time`/`end_time` (overnight blocks
allowed), `target_temp` (°F absolute, guard 40–90 °F post-conversion), plus
lifecycle (#359): `enabled` (default True — False "parks" the block, sweeps
never delete) and `expires_at` (naive **local** wall-clock datetime, null =
never; matches `<input type="datetime-local">`). Rules verified in
`routes.py`: overlap is rejected only between *enabled* blocks; an enabled
block cannot be created already-expired; the scheduler's
`schedule_expiry_sweep` job auto-disables expired blocks but lets a
currently-running block finish first.
Two more per-schedule fields, both nullable and both defaulting to `None`
(unset) so every pre-existing block reads back unchanged:
- `deadband_override` (#517) — °F **delta**, 0–10 °F post-conversion, shared
validator (`_validate_deadband_override`) with the Layer 5 per-room field of
the same name; when set it replaces the room's/thermostat's deadband **only
while this block is the room's active source** (resolved by
`room_manager._effective_deadband`), inheriting the chain otherwise.
- `name` (#520) — optional display label; purely cosmetic (the engine never
reads it, uniqueness is not enforced), read back via the `display_name`
property which falls back to `id` when unset — needed because a GUID makes
a poor human-facing name in MQTT Discovery (#519).
`POST …/schedules/{id}/copy` clones days/times/target **and** the two fields
above to other rooms — copies are enabled+never-expiring, and a conflicting
copy is created **disabled** with status `created_disabled_conflict`.
**Room override / temporary hold** (`POST /api/rooms/{room_id}/override`;
`DELETE` same path clears; `GET /api/overrides` lists live holds — reshaped by
#576, verified 2026-09): `target_temp` (40–90 °F post-conversion),
`duration_hours` (default 2.0, guard **> 0 and ≤ 8** — pre-#576 the bound was
0–8760; error text "duration_hours must be greater than 0 and at most 8"),
`respect_eco` (bool, default False — Eco opt-IN; the default preserves #419
"holds are never Eco-relaxed"; column `room_overrides.respect_eco`, migration
20). Expired holds are **deleted** by the engine sweep and event-logged
(contrast #359 schedules, which expiry only disables). UI: shared `HoldModal`
(Dashboard / Rooms / Schedules) with preset durations 1/2/4/6/8 h. MQTT's
hold control sends neither duration nor eco flag → REST defaults apply; the
MCP `set_room_override` tool takes both and enforces the same (0, 8] bound.
Priority: override > schedule > presence holdover. Docs:
`docs/temperature-holds.md`.
## The temperature-field registry (3-file lockstep)
`TEMPERATURE_FIELDS` in `routes.py:425` is the Python source of truth for
every body key converted at the write boundary. Kinds: `absolute`,
`absolute_nullable`, `delta`, `delta_nullable`. Current entries (19):
`default_temp`, `min_setpoint`, `max_setpoint`, `deadband`, `overshoot_delta`,
`cooling_lockout_below_f`, `system_wide_temp`, `temp_offset`,
`deadband_override`, `ambient_suppression_min_differential`,
`ambient_suppression_deadband`, `eco_cooling_outdoor_threshold`,
`eco_cooling_full_drift_temp`, `eco_cooling_max_drift`,
`eco_heating_outdoor_threshold`, `eco_heating_full_drift_temp`,
`eco_heating_max_drift`, `eco_hysteresis_band`, `target_temp`. Note
`deadband_override` is one entry covering **two** write boundaries (per-room
#277 and per-schedule #517 — same kind/bounds, so the registry (keyed by field
name) only needs one row); likewise each `eco_*` entry covers both the
non-null thermostat path and the nullable room-override path. `eco_mode_enabled`
is a bool, not registered here. Mirrored in `e2e/tests/temperature-fields.ts`
(20 `field:` entries — the extra one is a type declaration, not a data row);
parity + `// @covers:` tags enforced by
`smart_vent/backend/tests/test_temperature_field_parity.py`.
---
## ADD-A-KNOB checklists
Before touching anything, load `plenum-change-control` for gating/evidence.
Remember the CLAUDE.md 100% rule: **every backend tunable gets a UI control**
in the same change.
### A. New `config.yaml` option
1. Add to `options:` AND `schema:` in `smart_vent/config.yaml`.
2. Add a `get_config '<key>' '<default>'` read + `export <UPPER_KEY>=…` in `smart_vent/run.sh` (the parity test greps for `bashio::config '<key>'` usage — `test_addon_config.py` fails otherwise).
3. Read the env var in the backend (`os.environ.get`) with the same default.
4. Verify: `cd smart_vent && python -m pytest backend/tests/test_addon_config.py -q`.
### B. New temperature field on a write boundary
(Gates and reviewer evidence: `plenum-change-control` §2.1; parity-rule
mechanics and failure texts: `plenum-validation-and-qa` §5. This checklist is
the catalog-side companion, not the owner.)
1. Backend: convert with `_to_f` (absolute) or `_delta_to_f` (delta) from `backend/units.py`; validate the **°F value** after conversion (40–90 °F for user targets, per `.jules/sentinel.md`); pick nullable semantics deliberately.
2. Register in `TEMPERATURE_FIELDS` in `routes.py` with the right kind — a wrong absolute/delta kind silently corrupts data.
3. Register in `e2e/tests/temperature-fields.ts` (`field`, `kind`, `ui`, `endpoints`).
4. If `ui: true`: add a round-trip test in `e2e/tests/temperature-units.spec.ts` tagged `// @covers: <field>`.
5. Frontend form: init via `toDisplay`/`toDisplayDelta`, submit the **raw display value** — never `toStorage` on outgoing payloads (#231; contract owned by `plenum-architecture-contract`).
6. Tests: `TestToF`-style unit test + a Celsius-mode integration test (set `client.app["scheduler"]._active_unit = "C"`, restore in `finally`).
7. UI change ⇒ regenerate both `-Fahrenheit-` and `-Celsius-` E2E goldens (see CLAUDE.md pitfall 8).
8. Verify: `cd smart_vent && python -m pytest backend/tests/test_temperature_field_parity.py -q`.
### C. New `system_settings` flag (mirror the `mcp_enabled` / `mqtt_enabled` pattern — verified in `scheduler.py:302-341`)
1. Scheduler: private cached field (`self._flag`), loaded in startup **and** `reload_from_db()`; sync getter `get_flag()`; async `set_flag()` that (a) updates the cache, (b) `db.set_system_setting(...)` as `"1"/"0"`, (c) logs, (d) broadcasts a WS event `flag_changed` via `self._broadcast` if set. If the flag affects HVAC behavior, also call `_reset_and_reevaluate(...)` (see `set_dev_mode`/`set_vacation_mode`).
2. Routes: GET exposure (piggyback `/api/system/status` or `/api/settings`) + a POST setter that calls the scheduler setter and `emit(...)`s an event-log entry. Every route needs `@docs` + `@response_schema` (enforced by `test_api_spec_enforcement.py`).
3. Frontend: `api.ts` functions, a UI control (App header toggle for system-level flags), and a listener for the WS `*_changed` event to keep the UI live (see `mcp_enabled` handling in `App.tsx`).
4. Tests: integration test toggling via the API and asserting persistence + broadcast.
---
## Provenance and maintenance
Facts date-stamped 2026-09, v0.35.0. This pass re-verified every layer against
the current repo: Layer 1 (`config.yaml` gained `require_auth`, seven `oidc_*`
options, `plenum_external_url`, and seven `mqtt_*` options since #373/#464/#519
shipped), Layer 2 (nine env vars added: `REQUIRE_AUTH`, the seven `OIDC_*` /
`PLENUM_EXTERNAL_URL`, `SUPERVISOR_HOST`, `PLENUM_SESSION_SECRET`, the seven
`MQTT_*` vars, `ADDON_SLUG`, `PLENUM_CLOCK_OVERRIDE`, `PLENUM_MCP_STATELESS`),
Layer 3 (`mqtt_enabled`, `theme`, and the `migration_eco_defaults_v1` sentinel
added), Layer 4/5 (the seven Eco Mode fields + `eco_suspend_until` added to
`ThermostatConfig`, the same seven nullable Eco fields added to `Room`), Layer
6 (`Schedule.deadband_override` and `Schedule.name` added), and the
temperature-field registry (grew from 12 to 19 entries — the seven Eco fields).
Re-verification one-liners (run from repo root):
- Layer 1: `cat smart_vent/config.yaml` ; `grep -n "get_config\|export" smart_vent/run.sh`
- Layer 2: `grep -rn "os.environ\|os.getenv" smart_vent/backend/ --include="*.py" | grep -v tests`
- Layer 3 keys: `grep -rhoE '(get|set)_system_setting\([^,]+, "[a-z_]+"' smart_vent/backend/ --include="*.py" | grep -oE '"[a-z_]+"' | sort -u`
- Layer 3 defaults/sentinels: `grep -n "SENSOR_STALE_AFTER_MIN" smart_vent/backend/engine/cycle_engine.py` ; `grep -n "retention_days" smart_vent/backend/api/routes.py` ; `grep -n "sentinel = " smart_vent/backend/db.py`
- Layer 4/5/6 fields+defaults: `sed -n '35,455p' smart_vent/backend/models.py`
- Guards: `grep -n "_temp_range_error\|_THERMO_NUMERIC_BOUNDS\|_ECO_FIELD_SPECS\|_validate_deadband_override\|40 <=\|8760\|1440" smart_vent/backend/api/routes.py`
- Hold guard + eco flag (#576): `grep -n "duration_hours\|respect_eco" smart_vent/backend/api/routes.py smart_vent/backend/models.py`
- Registry: `sed -n '425,461p' smart_vent/backend/api/routes.py` ; `cat e2e/tests/temperature-fields.ts`
- mcp_enabled/mqtt_enabled/theme pattern: `sed -n '302,341p' smart_vent/backend/scheduler.py`
- MQTT broker/prefix resolution: `sed -n '155,205p' smart_vent/backend/mqtt/config.py`
- Auth env parsing: `sed -n '180,210p' smart_vent/backend/main.py`
- Parity tests: `cd smart_vent && python -m pytest backend/tests/test_addon_config.py backend/tests/test_temperature_field_parity.py -q` (needs `pip install ".[dev]"`; not executed while authoring this skill — deps not verified installed)
Volatile line numbers cited (routes.py:425, scheduler.py:302-341, cycle_engine.py:56,
db.py:3205) will drift; the greps above re-locate them.