Comprehensive risk management skill implementing ISO 14971:2019 methodology for medical device risk analysis
Scanned 9/2/2026
Install to Claude Code
npx -y skills add a5c-ai/babysitter --skill iso14971-risk-analyzer --agent claude-codeInstalls into .claude/skills of the current project.
Are you the author of Iso14971 Risk Analyzer?
Add the live security badge to your README — it updates automatically with every re-scan.
[](https://www.skillsdirectory.com/skills/a5c-ai-iso14971-risk-analyzer-babysitter)More formats (shields.io, HTML) on the badges page.
---
name: iso14971-risk-analyzer
description: Comprehensive risk management skill implementing ISO 14971:2019 methodology for medical device risk analysis
allowed-tools:
- Read
- Write
- Glob
- Grep
- Edit
- Bash
metadata:
specialization: biomedical-engineering
domain: science
category: Risk Management
skill-id: BME-SK-008
graph:
domains: [domain:biomedical-engineering]
skillAreas: [skill-area:statistical-analysis, skill-area:data-analysis, skill-area:compliance-automation]
workflows: [workflow:experiment-design, workflow:peer-review-cycle]
roles: [role:biomedical-engineer, role:research-engineer]
---
# ISO 14971 Risk Analyzer Skill
## Purpose
The ISO 14971 Risk Analyzer Skill implements comprehensive risk management methodology per ISO 14971:2019 for medical devices, supporting hazard identification, risk estimation, risk control, and benefit-risk analysis throughout the device lifecycle.
## Capabilities
- Hazard identification questionnaire generation
- Hazardous situation analysis templates
- Risk estimation matrix configuration
- Risk acceptability criteria setup
- Risk control measure tracking
- Residual risk evaluation
- Benefit-risk analysis documentation
- Risk management plan templates
- Risk management report generation
- Post-production risk monitoring
- Risk control verification tracking
## Usage Guidelines
### When to Use
- Establishing risk management plans
- Conducting hazard analyses
- Evaluating risk acceptability
- Documenting benefit-risk determinations
### Prerequisites
- Device intended use defined
- Reasonably foreseeable misuse identified
- Risk acceptability criteria established
- State of the art research completed
### Best Practices
- Begin risk management at concept phase
- Maintain risk management file throughout lifecycle
- Review risks at each design phase gate
- Integrate with post-market surveillance
## Process Integration
This skill integrates with the following processes:
- Medical Device Risk Management (ISO 14971)
- Human Factors Engineering and Usability
- 510(k) Premarket Submission Preparation
- EU MDR Technical Documentation
## Dependencies
- ISO 14971:2019 standard
- Risk matrix templates
- Hazard databases
- Safety standards (IEC 60601, IEC 62366)
- Post-market data sources
## Configuration
```yaml
iso14971-risk-analyzer:
risk-categories:
- clinical
- electrical
- mechanical
- software
- biocompatibility
- sterility
- usability
probability-levels: 5
severity-levels: 5
acceptability-criteria:
ALARP: true
state-of-art: true
```
## Output Artifacts
- Risk management plans
- Hazard analysis worksheets
- Risk estimation matrices
- Risk control documents
- Residual risk evaluations
- Benefit-risk analyses
- Risk management reports
- Risk control verification records
## Quality Criteria
- All reasonably foreseeable hazards identified
- Risk estimation is systematic and documented
- Risk control measures are verified effective
- Residual risks are acceptable per criteria
- Benefit-risk analysis supports intended use
- Documentation meets ISO 14971:2019 requirements
Is this your skill, or is something wrong with this listing? Request removal or report an issue. Author removals are honored within 72 hours.
No comments yet. Be the first to comment!